問題

  • NSMモジュールのDIMM障害に関する以下のエラーがイベントログに報告されます:

[Node-01: dsa_worker3: ses.status.dimm.error:error]: NS224NSM100 (S/N SHFGBXXXXXXXX) shelf 0 on channel 0x DIMM failure for Dimm Element 8: not installed or failed. This element is on the DIMM slot 4 in the bottom shelf module (B).

 [Node-01: dsa_worker3: ses.status.dimm.threshErr:alert]: NS224NSM100B  shelf 1 on channel 0x DIMM threshold failure error for Dimm Element 3: critical status. This element is on the DIMM slot 1 in the bottom shelf module (B).

cluster::> storage shelf show -instance
DIMM:
ID Mod Type Size Speed Status Location
--- --- ---- ---- ------- ------------ -------------------------------
1 A DIMM 8GB 2666Mhz normal DIMM slot 1 in the top shelf module (A)
2 A DIMM 8GB 2666Mhz normal DIMM slot 2 in the top shelf module (A)
3 A DIMM 8GB 2666Mhz normal DIMM slot 3 in the top shelf module (A)
4 A DIMM 8GB 2666Mhz normal DIMM slot 4 in the top shelf module (A)
5 B DIMM 8GB 2666Mhz normal DIMM slot 1 in the bottom shelf module (B)
6 B DIMM 8GB 2666Mhz normal DIMM slot 2 in the bottom shelf module (B)
7 B DIMM 8GB 2666Mhz normal DIMM slot 3 in the bottom shelf module (B)
8 B error DIMM slot 4 in the bottom shelf module (B)
  • storage show fault出力において、ステータスが不明または重大と報告される場合:

cluster::> system node run -node <node> storage show fault

DIMM:
Element Status            Status Bytes  Status Descriptions
  1 [NSM100 A]   : OK         01,00,00,00
  2 [NSM100 A]   : OK         01,00,00,00
  3 [NSM100 A]   : OK         01,00,00,00
  4 [NSM100 A]   : OK         01,00,00,00
  5 [NSM100 B]   : OK         01,00,00,00
  6 [NSM100 B]   : OK         01,00,00,00
  7 [NSM100 B]   : OK          06,00,00,00
  8 [NSM100 B]   : UNKNOWN       01,00,00,00

DIMM:
Element Status            Status Bytes  Status Descriptions
  8 [NSM100 B]   : NOT AVAILABLE   07,00,00,00  

DIMM:
Element Status            Status Bytes  Status Descriptions
  3 [NSM100B B]  : CRITICAL     02,00,00,01

  • ディスク冗長性障害アラートが表示される場合があります

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.