メインコンテンツへスキップ

DS212C Fan4の故障

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

環境

  • FAS / AFF システム
  • DS212C

問題

  • EMSログ:

Tue Feb 24 10:00:00 +0000 [node05-01: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.

  • ONTAPシステムマネージャには、ファン4に障害が発生したことが示されています。

clipboard_45d8a885-2c26-4a80-934a-4d18d643f02f.png

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.