メインコンテンツまでスキップ

PSUセンサーのDS2246シェルフOT警告

Views:
9
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw<a>2009977107</a>
Last Updated:

環境

  • ONTAP 9
  • DS2246

問題

  • ストレージ障害の出力を確認すると、次のエラーが表示されます。

Enclosure Status: non-critical
Channel: 0a
Shelf: 12
Shelf Type: DS2246
Product Serial Number: SHFFG1451000046
Module Type: IOM6
Temperature Sensors:
Element Status         Status Bytes  Status Descriptions  
1: OK                01,00,24,00  
2: OK                01,00,27,00  
3: OK                01,00,2E,00  
4: OK                01,00,47,00  
5: OK                01,00,30,00  
6: NONCRITICAL       03,00,58,04   OT WARNING 
7: OK                01,00,2C,00  
8: OK                01,00,2E,00

  • EMSでは次のアラートも確認できます。

3/14/2024 15:48:34  rpsdlxx1         ALERT         ses.status.temperatureWarning: DS2246 (S/N SHFFG1451000046) shelf 12 on channel 0a temperature warning for Temperature sensor 6: non-critical status; overtemperature warning. Current temperature: 66 C (150 F). This module is on the rear of the shelf on the lower right power supply.
3/14/2024 15:48:34  rpsdlxx2         ALERT         ses.status.temperatureWarning: DS2246 (S/N SHFFG1451000046) shelf 12 on channel 0c temperature warning for Temperature sensor 6: non-critical status; overtemperature warning. Current temperature: 66 C (150 F). This module is on the rear of the shelf on the lower right power supply.
3/14/2024 15:48:25  rpsdlxx1         ERROR         monitor.shelf.warning: Fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 