メインコンテンツへスキップ

DS460Cシェルフの温度センサーが不明で、DCMが重大です

Views:
2
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

環境

  • ONTAP 9
  • DS460Cディスクシェルフ

問題

  • イベントログでは次のアラートが報告されます。

[Node-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "10", module "B", drawer "2", PHY"0" is reporting an unknown link rate.
[Node-01: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 10a. Check fans, power supplies, disks, and temperature sensors.

  • AutoSupportのSTORAGE-SHELF セクションに、該当するモジュールを通じて該当するドロワーの不明なリンク速度が表示されます。

Shelf name:   9b.shelf10
Shelf id:    10
Channel:     9b
Module:     B
Shelf UID:    50:XX:XX:XX:XX:XX:XX:XX
Shelf S/N:    SHJGDXXXX00380
Term switch:   N/A
Shelf state:   ONLINE
Module state:  OK

           Partial Path   Link   Invalid   Running    Loss   Phy     CRC    Phy
Disk      Port   Timeout     Rate    DWord   Disparity   Dword   Reset    Error   Change
Id       State   Value (ms)   (Gb/s)   Count   Count     Count   Problem   Count   Count
--------------------------------------------------------------------------------------------------
[DCM1.0] OK        0     12.0     0       0     0     0      0     7
[DCM1.1] OK        0     12.0     0       0     0     0      0     7
[DCM1.2] OK        0     12.0     0       0     0     0      0     7
[DCM1.3] OK        0     12.0     0       0     0     0      0     7
[DCM2.0] UNKWN LNK   0      NA    0       0     0     0      0     8
[DCM2.1] UNKWN LNK   0      NA    0       0     0     0      0     8
[DCM2.2] UNKWN LNK   0      NA    0       0     0     0      0     8
[DCM2.3] UNKWN LNK   0      NA    0       0     0     0      0     8
[DCM3.0] OK        0     12.0     0       0     0     0      0     7

  • storage-faultセクションに、該当するドロワーにマッピングされている温度センサーがunknown、ドロワーがcriticalと表示されます。

Enclosure Status: information
Channel: 1d
Shelf: 10
Shelf Type: DS460-12
Product Serial Number: SHJGDXXXX00380
Module Type: IOM12B

Temperature Sensors:
Element Status      Status Bytes  Status Descriptions  
 20: OK         01,00,35,00   
 21: UNKNOWN      06,00,33,00   
 22: OK         01,00,36,00   
 23: OK         01,00,35,00   
 24: OK         01,00,35,00   
 25: OK         01,00,39,00   
 26: UNKNOWN      06,00,3A,00   
 27: OK         01,00,3B,00   
 28: OK         01,00,3A,00   
 29: OK         01,00,3A,00  

Drawers Control Module:
Element Status            Status Bytes  Status Descriptions
  1 [IOM12B A]   : OK         01,00,01,01   REPORT, TYPE BIT0
  2 [IOM12B A]   : OK         01,00,01,01   REPORT, TYPE BIT0
  3 [IOM12B A]   : OK         01,00,01,01   REPORT, TYPE BIT0
  4 [IOM12B A]   : OK         01,00,01,01   REPORT, TYPE BIT0
  5 [IOM12B A]   : OK         01,00,01,01   REPORT, TYPE BIT0
  6 [IOM12B B]   : OK         01,00,01,01   REPORT, TYPE BIT0
 7 [IOM12B B]   : CRITICAL     02,40,00,00  FAIL
  8 [IOM12B B]   : OK         01,00,01,01   REPORT, TYPE BIT0
  9 [IOM12B B]   : OK         01,00,01,01   REPORT, TYPE BIT0
 10 [IOM12B B]   : OK         01,00,01,01   REPORT, TYPE
BIT0

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.