環境

  • イーサネット ポート

問題

  • データポートリンク停止イベント。例: 
[node_name: intr: net.ifgrp.lacp.link.inactive:error]: ifgrp a0a, port e0c has transitioned to an inactive state. The interface group is in a degraded state.
[node_name: intr: net.ifgrp.lacp.link.active:notice]: ifgrp a0a, port e0c has transitioned to the active state.
[node_name: intr: netif.linkDown:info]: Ethernet e0c: Link down, check cable.
[node_name: intr: netif.linkUp:info]: Ethernet e0c: Link up.
...
[node_name: intr: net.ifgrp.lacp.link.inactive:error]: ifgrp a0a, port e0c has transitioned to an inactive state. The interface group is in a degraded state.
[node_name: intr: net.ifgrp.lacp.link.active:notice]: ifgrp a0a, port e0c has transitioned to the active state.
[node_name: vifmgr: vifmgr.portdown:notice]: A link down event was received on node node_name, port e0c.
[node_name: intr: netif.linkDown:info]: Ethernet e0c: Link down, check cable.
  • IFCONFIG -vvv ポートのrx電力を0と表示します。

        status: no carrier
        plugged: SFP/SFP+/SFP28 10G Base-SR (LC)
        vendor: Intel Corp PN: FTLX8574D3BCV-IT SN: A41A571 DATE: 2020-06-30
        module temperature: 32.03 C Voltage: 3.37 Volts
       RX: 0.00 mW (-26.78 dBm) TX: 0.22 mW (-6.57 dBm)

  • 問題 は再装着後も残ります
  • 問題 のポートはup-admin down/upのままです
  • 問題 は、スイッチ側からポートshut/no shutが設定されたままになります
  • 問題 にはifgrpへのポートの追加/削除は引き続き行われます
  • ポートは別のSFP+で正常に動作

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.