"system health alert show" は DegradedOnlineShelfPort_Alert を報告します
環境
問題
system health alert show
DegradedOnlineShelfPort_Alertを報告します。
::> system health alert show
Node: node01
Alert ID: DegradedOnlineShelfPort_Alert
Resource: Shelf 1.13
Probable Cause: Shelf-to-shelf connection between disk shelves 1.13 1
port and 1.12 3 port have 1 inactive PHYs on IOM B.
Possible Effect: Inactive PHYs might cause degraded link performance.
Corrective Actions: 1. Consult the guide applicable to your IOM12B disk shelf to review cabling rules and complete the SAS cabling worksheet for your system.
2. Verify that disk shelf 1.13 has disabled PHYs by using the "storage shelf show -shelf 1.13 -port" command.
3. If the disk shelves have multiple paths to the node, reseat disk shelf 1.13 1 port cable on IOM B and disk shelf 1.12 3 port cable on IOM B.
4. Verify that the physical cable connection is secure
and operational, and replace the cable, if necessary.
Node: CJ4DXNASTMP2_node02
Alert ID: DegradedOnlineShelfPort_Alert
Resource: Shelf 1.13
Probable Cause: Shelf-to-shelf connection between disk shelves 1.13 1
port and 1.12 3 port have 1 inactive PHYs on IOM B.
Possible Effect: Inactive PHYs might cause degraded link performance.
Corrective Actions: 1. Consult the guide applicable to your IOM12B disk shelf to review cabling rules and complete the SAS cabling worksheet for your system.
2. Verify that disk shelf 1.13 has disabled PHYs by using the "storage shelf show -shelf 1.13 -port" command.
3. If the disk shelves have multiple paths to the node, reseat disk shelf 1.13 1 port cable on IOM B and disk shelf 1.12 3 port cable on IOM B.
4. Verify that the physical cable connection is secure
and operational, and replace the cable, if necessary.
- シェルフ間のケーブルの交換は役に立ちません。
- IOMモジュールの取り付け直しは役に立ちません。