メインコンテンツまでスキップ

ディスク X316_HARIH06TA07 に障害が発生すると、システムのパフォーマンスに影響します

環境

  • FASシステム
  • ディスクモデル X316_HARIH06TA07

問題

  • ディスクモデルX316_HARIH06TA07に障害が発生したときに、パフォーマンスへの影響が発生しました。
  • ディスクで障害が発生すると、パフォーマンスは通常の状態に戻ります。

例:

[node01: wafl_exempt16: wafl.cp.toolong:error]: Aggregate aggr01_node01 experienced a long CP.
[node01: wafl_exempt13: wafl.cp.toolong:error]: Aggregate aggr01_node01 experienced a long CP.
[node01: disk_latency_monitor: shm.threshold.ioLatency:debug]: Disk 9a.02.4 has exceeded the expected IO latency in the current window with average latency of 72 msecs and average utilization of 85 percent. Highest average IO latency: 9a.02.4: 72 msecs; next highest IO latency: 10a.10.0: 9 msecs. Disk 9a.02.4 Shelf 2 Bay 4 [NETAPP   X316_HARIH06TA07 NA00] S/N [XXXXXX] UID [5000CCA2:3107A1DC:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[node01: disk_latency_monitor: shm.threshold.ioLatency:debug]: Disk 9a.02.4 has exceeded the expected IO latency in the current window with average latency of 120 msecs and average utilization of 92 percent. Highest average IO latency: 9a.02.4: 120 msecs; next highest IO latency: 10a.10.0: 9 msecs. Disk 9a.02.4 Shelf 2 Bay 4 [NETAPP   X316_HARIH06TA07 NA00] S/N [XXXXXXB] UID [5000CCA2:3107A1DC:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[node01: disk_latency_monitor: shm.threshold.highIOLatency:error]: Disk 9a.02.4 exceeds the average IO latency threshold and will be recommended for failure.
[node01: disk_latency_monitor: scsi.debug:debug]: shm_setup_for_failure disk 9a.02.4 (S/N 1EV463TB) error 200000h
[node01: config_thread: callhome.fdsk.fault:error]: Call home for FILESYSTEM DISK FAILED Shelf 2, Bay 4, Model [X316_HARIH06TA07], S/N [XXXXXX]

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.