EMS の報告で「 The NVMEM battery is too cold ( -17 C )」というメッセージがバッテリ学習サイクル中に表示されます
環境
- FAS2620
- FAS8200
- ONTAP 9
- サービス プロセッサ(SP)
問題
- SP から
events all
バッテリ温度エラーおよびバッテリパックの無効エラーが報告される。
[IPMI.notice]: 3301 | 02 | EVT: 0301ffff | Bat_Lrn_Active | Assertion Event, "State Asserted"
[IPMI.notice]: 3401 | 02 | EVT: 0150ef05 | Bat_Temp | Assertion Event, "Lower Non-critical going low"
[IPMI.notice]: 3501 | 02 | EVT: 0152ef00 | Bat_Temp | Assertion Event, "Lower Critical going low"
[IPMI.notice]: 3601 | 02 | EVT: 0301ffff | Bat_Pack_Invalid | Assertion Event, "State Asserted"
[IPMI.notice]: 3701 | 02 | EVT: 0301ffff | Attn_Sensor1 | Assertion Event, "State Asserted"
[IPMI.notice]: 3801 | 02 | EVT: 0300ffff | Attn_Sensor1 | Assertion Event, "State Deasserted"
[IPMI.notice]: 3901 | 02 | EVT: 81522e00 | Bat_Temp | Deassertion Event, "Lower Critical going low"
[IPMI.notice]: 3a01 | 02 | EVT: 81502e05 | Bat_Temp | Deassertion Event, "Lower Non-critical going low"
[IPMI.notice]: 3b01 | 02 | EVT: 0300ffff | Bat_Pack_Invalid | Assertion Event, "State Deasserted"
[IPMI.notice]: 3c01 | 02 | EVT: 0301ffff | Attn_Sensor1 | Assertion Event, "State Asserted"
[IPMI.notice]: 3d01 | 02 | EVT: 0150ef05 | Bat_Temp | Assertion Event, "Lower Non-critical going low"
[IPMI.notice]: 3e01 | 02 | EVT: 0152ef00 | Bat_Temp | Assertion Event, "Lower Critical going low"
[IPMI.notice]: 3f01 | 02 | EVT: 0301ffff | Bat_Pack_Invalid | Assertion Event, "State Asserted"
[IPMI.notice]: 4001 | 02 | EVT: 0300ffff | Attn_Sensor1 | Assertion Event, "State Deasserted"
EMS log
両方の HA ノードからセンサー 15 の温度エラーが報告されます。
nvmem.battery.tempLow:alert]: The NVMEM battery is too cold (-17 C). To prevent data loss, the system will shut down in 24 hours.
nvmem.battery.temp.normal:info]: The NVMEM battery temperature is normal.
nvmem.battery.packValid:notice]: A valid NVMEM battery pack is present.
ses.status.temperatureWarning:alert]: DS212-12 (S/N SHJSGXXXXXXXXXX) shelf 0 on channel 0a temperature warning for Temperature sensor 15: not installed or failed. Current temperature: 46 C (114 F). `O\252\207r.
ses.status.temperatureInfo:info]: DS212-12 (S/N SHJSGXXXXXXXXXX) shelf 0 on channel 0a temperature information for Temperature sensor 15: normal status.
ses.status.temperatureWarning:alert]: DS212-12 (S/N SHJSGXXXXXXXXXX) shelf 0 on channel 0b temperature warning for Temperature sensor 15: not installed or failed. Current temperature: 46 C (114 F). `O\252\207r.
ses.status.temperatureInfo:info]: DS212-12 (S/N SHJSGXXXXXXXXXX) shelf 0 on channel 0b temperature information for Temperature sensor 15: normal status.
- このエラーは約 30 秒で回復しました。
- から
SP-LATEST-IPMI
、このエラー中にバッテリ学習サイクルが実行されていました。
LrnCycleStartDate : 22-03-17-12:00
LrnCycleStartFCC : 0x0546
LrnCycleEndFCC : 0x054e
LrnCycleEndDate : 22-03-17-22:59