環境

  • AFF機種
  • FAS機種
  • BMC/SPを最新バージョンに更新

問題

  • 理由Battery PCT capacity criticalによる緊急シャットダウン。
Jan 02 21:43:08 [nodename:nvmem.battery.fccLowCrit:EMERGENCY]: The NVMEM battery full-charge capacity is critically low (15 ). To prevent data loss, the system will shut down in 20 minutes.
Jan 02 21:43:59 [nodename:nvmem.battery.capLowCrit:EMERGENCY]: The NVMEM battery capacity is critically low (0 cycles). To prevent data loss, the system will shut down in 20 minutes.
Jan 02 21:44:08 [nodename:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (full charge capacity low) CRITICAL.
Jan 02 21:44:29 [nodename:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (capacity low) CRITICAL.
Jan 02 22:00:00 [nodename:monitor.nvramLowBattery:EMERGENCY]: NVRAM battery is dangerously low.
Jan 02 22:03:09 [nodename:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery PCT capacity critical)
Waiting for PIDS: /usr/sbin/rpcbind 1208.
Terminated
.
Uptime: 117d7h1m47s
System powering down...
  • ノードシャーシ前面の警告LEDが点灯します。
  • BMC/SP ログエントリ:

[IPMI.emergency]: env_mgr triggers OS halt:Battery PCT capacity
[IPMI.notice]: 001e | 02 | EVT: 6f03ffff | Sensor 255 | Assertion Event, "Storage OS graceful shutdown"
[IPMI.notice]: 001f | 02 | EVT: 0150008f | PVCCIN_CPU | Assertion Event, "Lower Non-critical going low " | Reading: 0.000 | Threshold: 1.502
[IPMI.notice]: 0020 | 02 | EVT: 01520077 | PVCCIN_CPU | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 1.249

  • バッテリーの状態:

Bat Present                 PRESENT
Bat Temp            failed            -- C         0 C         5 C        56 C        60 C
Bat Volt            failed            -- mV     5500 mV     5600 mV     8500 mV     8600 mV
Bat Pct Capacity    failed            -- %        39 %        44 %        --          --
Bat Curr            failed            -- mA       --          --        1520 mA     1800 mA
Bat Rem Cap         not_available     -- mA*hr    --          --          --          --
Bat Full Cap        failed            -- mA*hr    --          --          --          --
Bat Charge Curr     failed            -- mA       --          --        2400 mA     2900 mA
Bat Charging State  failed             --
Bat Charge Volt     failed            -- mV       --          --        8900 mV     9000 mV
Bat Initial FCC     failed            -- mA*hr    --          --          --          --
Bat Dstg Cycles     failed            -- cycles    2 cycles    5 cycles   --          --
Bat Power Fault                      GOOD
Bat Dcharge FET     failed             --
Bat Charge FET      failed             --
Bat Cycle Count     not_available     -- cycles   --          --          --          --
Bat Learning Active not_available      --
Bat Pack Invalid    failed             --

  • コントローラの電源を入れた後も問題が残る
  • 利用可能な最新のBMC/SPバージョンでも問題が残る
  • 緊急シャットダウン後にブートできず、LOADERプロンプトも利用できない

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.