I/Oモジュールの変更後、環境シャットダウンシャーシが過熱状態になりました

Views:
38
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

環境

  • ONTAP 9
  • AFF A900、FAS9500
  • AFF A700 、 FAS9000

問題

  • あるタイプのモジュールから別のタイプのモジュールへのI/Oモジュール(カード)の交換中に、ノードでONTAP のリブート後に温度に関する問題が発生すると、環境がシャットダウンされます
  • たとえば、X91440A(40GbE)モジュールはX91153A(100GbE)モジュールに置き換えられました。

A900-6-147-148::*> Aug 16 11:08:37 [A900-6-147:vifmgr.clus.linkdown:EMERGENCY]: The cluster port e4e on node A900-6-147 has gone down unexpectedly.
Aug 16 11:08:39 [A900-6-147:vifmgr.clus.linkdown:EMERGENCY]: The cluster port e4a on node A900-6-147 has gone down unexpectedly.

Aug 16 11:12:53 [A900-6-147:monitor.chassisTemperature.cool:ALERT]: Chassis temperature is too cool: IO4 200G SW DieTmp is critical low (0 C).
Aug 16 11:12:54 [A900-6-147:monitor.shutdown.chassisUnderTemp:error]: Chassis temperature is too cold: Temp on I/O Slot4 is critical low. System will be shutdown in 2 minutes
Aug 16 11:12:54 [A900-6-147:monitor.chassisTemperature.cool:ALERT]: Chassis temperature is too cool: IO4 200G CPLD DieTmp is critical low (0 C).
Aug 16 11:12:54 [A900-6-147:monitor.chassisTemperature.ok:notice]: Chassis temperature is ok.
***OS2SP configured successfully***Aug 16 11:13:24 [A900-6-147:callhome.chassis.undertemp:EMERGENCY]: Call home for CHASSIS UNDER TEMPERATURE SHUTDOWN
Aug 16 11:13:27 [A900-6-147:discover.6500.unsupported:notice]: FC-to-SAS bridge ATTO 6500N discovery is disabled.
Reservation conflict found on this node's disks!

Aug 16 11:16:56 [A900-6-147:monitor.ioCard.degraded:ALERT]: IO card is degraded: IO4 200G Hot Swap Cur is critical high (1920 mV).
Aug 16 11:17:16 [A900-6-147:monitor.ioCard.degraded:ALERT]: IO card is degraded: IO4 200G VCORE CX6 is critical high (4640 mV).
Continuing boot...

Aug 16 11:18:59 [A900-6-147:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Temperature critical)

  • ノードがリブートしてONTAP に戻ったあとにノードがリカバリされる

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.