メインコンテンツへスキップ

FAS2820がNVRAM battery Bat Dstg Cycles warnlowを報告する

Views:
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

環境

  • FAS2820
  • ONTAP 9

問題

  • 次の ems ログが HA Group Notification (BATTERY_LOW) ALERT に表示されます。

Tue Feb 04 11:09:01 +0900 [Cluster02-01: statd: monitor.nvramLowBattery:EMERGENCY]: NVRAM battery is dangerously low.
Tue Feb 04 11:09:01 +0900 [Cluster02-01: statd: monitor.nvramLowBattery.notice:notice]: If the NVRAM battery is dangerously low, the system shuts down automatically every 24 hours to encourage you to replace it. If you reboot the system it will run for another 24 hours before shutting down.
Tue Feb 04 11:09:01 +0900 [Cluster02-01: statd: callhome.battery.low:alert]: Call home for BATTERY_LOW.

  • 次の BMC ログとともにノードがダウンしています。

Record 438: Tue Feb 04 01:52:46.873400 2025 [IPMI.emergency]: env_mgr triggers OS halt:Battery remaining des
Record 439: Tue Feb 04 02:12:05.276329 2025 [IPMI.notice]: 0124 | 02 | EVT: 81520402 | Bat_Dstg_Cycles | Deassertion Event, "Lower Critical going low " | Reading: 4.000 | Threshold: 2.000

  • Bat Dstg サイクルが5サイクル未満です。

Bat FRU LED                 OFF
Battery RemCap Desc            READY
Battery Charge Failed?           FALSE 
Battery Charge Bad?            FALSE 
Battery Capacity Message          GOOD
Voltage Spike Frequency  normal        0      --      --      --       3
Voltage Status               GOOD
Bat Present                PRESENT
Bat Temp          normal       36 C      0 C      5 C     60 C     75 C
Bat Volt          normal      6800 mV    5500 mV    5600 mV    8500 mV    8600 mV
Bat Curr          normal      1000 mA     --      --     1200 mA    1520 mA
Bat Rem Cap        normal        1 W*hr    --      --      --      --
Bat Dstg Cycles      warnlow      3 cycles   2 cycles   5 cycles   --      --
Bat Full Cap        normal       16 W*hr    --      --      --      --
Bat Initial FCC      normal       20 W*hr    --      --      --      --
Bat Charge Curr      normal      1000 mA     --      --     2200 mA    2300 mA
Bat Charge Volt      normal      8200 mV     --      --     8900 mV    9000 mV
Bat Dcharge FET                ON
Bat Charge FET                ON
Bat Cycle Count      normal        0 cycles   --      --      --      --
Bat Learning Active             OFF
Bat Pack Invalid               OK
Bat Charging State            CHARGING
Bat Pct Capacity      normal       80 %     39 %     44 %     --      --

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 