メインコンテンツへスキップ

SPエラーにより、電源メンテナンス後にFAS8200がブートしない

Views:
26
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2009412481</a>
Specialty:
hw
Last Updated:

環境

FAS8200

問題

  • 電源のメンテナンス後にFAS8200をブートできず、以下のSPエラーログが表示される:
Jan 1 00:00:47 (none) : [381 WARNING][hal_api.c:407]hal_api.c : error finding sensor 200 device table entry
Jan 1 00:02:40 (none) hsam[347]: [347 CRITICAL][semaph.c:331]semtimedop error
Jan 1 00:13:36 (none) oem_ipmi: [1858 WARNING][libbattery.c:488]Read from ChargeOption Register failed
Jan 1 00:13:36 (none) oem_ipmi: [1858 WARNING][libbattery.c:488]Read from ChargeCurrent Register failed
Jan 1 00:13:36 (none) oem_ipmi: [1858 WARNING][libbattery.c:488]Read from ChargeVoltage Register failed
Jan 1 00:13:36 (none) oem_ipmi: [1858 WARNING][libbattery.c:488]Read from ChargeInCurrent Register failed
Jan 1 00:13:36 (none) oem_ipmi: [1858 WARNING][libbattery.c:488]Read from ChargeManufID Register failed
Jan 1 00:13:36 (none) oem_ipmi: [1858 WARNING][libbattery.c:488]Read from ChargeDevID Register failed
Jan 1 00:13:37 (none) scratchpad: [1886 WARNING][scratchpad.c:588]Header signature mismatch found on BIOS region.
Jan 1 00:13:37 (none) scratchpad: [1886 WARNING][scratchpad.c:742]Decoding region 1 failed
Jan 1 00:13:37 (none) scratchpad: [1886 WARNING][scratchpad.c:588]Header signature mismatch found on ONTAP region.
Jan 1 00:13:37 (none) scratchpad: [1886 WARNING][scratchpad.c:756]Decoding region 2 failed
  •  コントローラの電源を再投入するか、取り付け直しても問題は解決しない。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • この記事は役に立ちましたか?