FAS9500でディスクconfig.SAS2DomainエラーのあとにMixed-Pathが表示される
環境
- FAS9500
- FAS / AFFシステム
問題
- 1つのconfig.SAS2Domainエラーの後、ノードがMixed-Pathになっています。
EMS:
[?] Mon Apr 07 18:07:36 +0900 [Node1: config_check: config.SAS2Domain:error]: Disk 1.12.27 is multipathed to the same SAS domain. The two disk ports must be in different SAS domains.
[?] Mon Apr 07 18:07:36 +0900 [Node1: config_check: callhome.dsk.config:error]: Call home for DISK CONFIGURATION ERROR
[?] Mon Apr 07 18:07:36 +0900 [Node1: start_asup_collector_thread: shelf.config.tomixedha:notice]: System has transitioned to a mixture of single, multi-path or quad-path storage configurations.
[?] Mon Apr 07 18:07:36 +0900 [Node1: start_asup_collector_thread: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED
sysconfig -a:
NetApp Release 9.15.1P7: Sat Jan 18 16:34:02 EST 2025
System ID: XXXXXXXXXX (Node1); partner ID: XXXXXXXXXX (Node2)
System Serial Number: XXXXXXXXXXXX (Node1)
System Rev: C0
System Storage Configuration: Mixed-Path HA
- この ディスクは1つのループにのみ表示されます。
sysconfig -a:
slot 1: SAS Host Adapter 1d (PMC-Sierra PM8072 rev. C, SAS, <UP>)
12.26: NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
12.27: NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
12.28: NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
slot 11: SAS Host Adapter 11b (PMC-Sierra PM8072 rev. C, SAS, <UP>)
12.26: NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
12.27: NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
12.28: NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
slot 7: SAS Host Adapter 7a (PMC-Sierra PM8072 rev. C, SAS, <UP>)
12.26: NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
12.28: NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
slot 11: SAS Host Adapter 11a (PMC-Sierra PM8072 rev. C, SAS, <UP>)
12.26: NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
12.28: NETAPP X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
ENCLOSURE BYPASSED B, BYPASSED B
このディスクで発生します。
ストレージ障害:
Enclosure Status: critical
Channel: 11a
Shelf: 12
Shelf Type: DS460-12
Product Serial Number: XXXXXXXXXXXX
Module Type: IOM12B
Disk Elements:
Element Status Status Bytes Status Descriptions
27 [Bay 3]: CRITICAL 02,03,10,04 ENCLOSURE BYPASSED B, BYPASSED B
- 問題はディスクの交換後も存続しました。