環境

  • FAS9500
  • FAS / AFFシステム

問題

  • 1つのconfig.SAS2Domainエラーの後、ノードがMixed-Pathになっています。
EMS:
[?]  Mon Apr 07 18:07:36 +0900 [Node1: config_check: config.SAS2Domain:error]: Disk 1.12.27 is multipathed to the same SAS domain. The two disk ports must be in different SAS domains.
[?]  Mon Apr 07 18:07:36 +0900 [Node1: config_check: callhome.dsk.config:error]: Call home for DISK CONFIGURATION ERROR
[?]  Mon Apr 07 18:07:36 +0900 [Node1: start_asup_collector_thread: shelf.config.tomixedha:notice]: System has transitioned to a mixture of single, multi-path or quad-path storage configurations.
[?]  Mon Apr 07 18:07:36 +0900 [Node1: start_asup_collector_thread: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED
sysconfig -a:
NetApp Release 9.15.1P7: Sat Jan 18 16:34:02 EST 2025
System ID: XXXXXXXXXX (Node1); partner ID: XXXXXXXXXX (Node2)
System Serial Number: XXXXXXXXXXXX (Node1)
System Rev: C0
System Storage Configuration: Mixed-Path HA
  • この ディスクは1つのループにのみ表示されます。
sysconfig -a:
slot 1: SAS Host Adapter 1d (PMC-Sierra PM8072 rev. C, SAS, <UP>)
12.26: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
12.27: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
12.28: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
 
slot 11: SAS Host Adapter 11b (PMC-Sierra PM8072 rev. C, SAS, <UP>)
12.26: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
12.27: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
12.28: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
 
slot 7: SAS Host Adapter 7a (PMC-Sierra PM8072 rev. C, SAS, <UP>)
12.26: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
12.28: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
 
slot 11: SAS Host Adapter 11a (PMC-Sierra PM8072 rev. C, SAS, <UP>)
12.26: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
12.28: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)
  • ENCLOSURE BYPASSED B, BYPASSED B このディスクで発生します。
ストレージ障害:
Enclosure Status: critical
Channel: 11a
Shelf: 12
Shelf Type: DS460-12
Product Serial Number: XXXXXXXXXXXX
Module Type: IOM12B
 
Disk Elements:
Element Status          Status Bytes  Status Descriptions
27 [Bay  3]: CRITICAL      02,03,10,04  ENCLOSURE BYPASSED B, BYPASSED B
  • 問題はディスクの交換後も存続しました。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 