- 1つのconfig.SAS2Domainエラーの後、ノードがMixed-Pathになっています。
EMS:
[?]  Mon Apr 07 18:07:36 +0900 [Node1: config_check: config.SAS2Domain:error]: Disk 1.12.27 is multipathed to the same SAS domain. The two disk ports must be in different SAS domains.[?]  Mon Apr 07 18:07:36 +0900 [Node1: config_check: callhome.dsk.config:error]: Call home for DISK CONFIGURATION ERROR[?]  Mon Apr 07 18:07:36 +0900 [Node1: start_asup_collector_thread: shelf.config.tomixedha:notice]: System has transitioned to a mixture of single, multi-path or quad-path storage configurations.[?]  Mon Apr 07 18:07:36 +0900 [Node1: start_asup_collector_thread: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILEDsysconfig -a:
 NetApp Release 9.15.1P7: Sat Jan 18 16:34:02 EST 2025System ID: XXXXXXXXXX (Node1); partner ID: XXXXXXXXXX (Node2)System Serial Number: XXXXXXXXXXXX (Node1)System Rev: C0System Storage Configuration: Mixed-Path HA- この ディスクは1つのループにのみ表示されます。
sysconfig -a:
 slot 1: SAS Host Adapter 1d (PMC-Sierra PM8072 rev. C, SAS, <UP>)12.26: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)12.27: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)12.28: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)slot 11: SAS Host Adapter 11b (PMC-Sierra PM8072 rev. C, SAS, <UP>)12.26: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)12.27: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)12.28: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)slot 7: SAS Host Adapter 7a (PMC-Sierra PM8072 rev. C, SAS, <UP>)12.26: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)12.28: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)slot 11: SAS Host Adapter 11a (PMC-Sierra PM8072 rev. C, SAS, <UP>)12.26: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)12.28: NETAPP  X377_SCBPE10TA07 NA01 9324.2GB 520B/sect (XXXXXXXX)- ENCLOSURE BYPASSED B, BYPASSED Bこのディスクで発生します。
ストレージ障害:
 Enclosure Status: criticalChannel: 11aShelf: 12Shelf Type: DS460-12Product Serial Number: XXXXXXXXXXXXModule Type: IOM12BDisk Elements:Element Status          Status Bytes  Status Descriptions27 [Bay  3]: CRITICAL      02,03,10,04  ENCLOSURE BYPASSED B, BYPASSED B- 問題はディスクの交換後も存続しました。