メインコンテンツまでスキップ

「Cluster」IPspaceからA250 e0dポートを削除できませんでした

Views:
64
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
network<a>2009120654.</a>
Last Updated:

環境

  • ONTAP 9.9
  • AFF A250

問題

  • 「Cluster」IPspaceから「Default」IPspaceへのA250 e0dポートの削除に失敗しました。
 
A250::> network port broadcast-domain show
 
IPspace Broadcast           Update
Name   Domain Name MTU   Port List  Status Details
------- ----------- ------ ----------------------------- --------------
Cluster Cluster   9000
              Node1:e0c  complete
              Node1:e0d  complete
              Node2:e0c  complete
              Node2:e0d  complete
 
A250::>network port modify -node Node1 -port e0d -ipspace default
 
Error: command failed: Port "e0d:" cannot be removed from IPspace "Cluster"because it is shared with the HA interconnect on this system.
  • e0dがIPspaceから削除されましたが、EMSが次のエラーメッセージを頻繁に報告し続けています。

3/28/2022 15:45:05 Node1 ERROR vifmgr.port.shareBd: Port e0d is shared with the HA or DR interconnect but has been moved from broadcast domain "Cluster" to broadcast domain "-" of IPspace "Default".

Cluster::*> network port show -ipspace Cluster

Node: Cluster1-Node1
                                                                       Ignore
                                                  Speed(Mbps) Health   Health
Port      IPspace      Broadcast Domain Link MTU  Admin/Oper  Status   Status
--------- ------------ ---------------- ---- ---- ----------- -------- ------
e0c       Cluster     -                up   9000  auto/25000 healthy  false
e0d       Cluster     -                up   9000  auto/25000 healthy  false

Node: Cluster1-Node2
                                                                       Ignore
                                                  Speed(Mbps) Health   Health
Port      IPspace      Broadcast Domain Link MTU  Admin/Oper  Status   Status
--------- ------------ ---------------- ---- ---- ----------- -------- ------
e0c       Cluster     -                up   9000 25000/25000 healthy  false
e0d       Cluster     -                up   9000 25000/25000 healthy  false

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.