メインコンテンツへスキップ

CSHM: ClusterSwitchConfig_Alert: 接続不良のため、1つ以上のノードが両方のクラスタスイッチに接続されていません

Views:
25
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

適用対象

  • ONTAP 9
  • AFFシステム
  • ASAシステム
  • FASシステム
  • クラスタスイッチヘルスモニタ(CSHM)AutoSupportメッセージ

問題

1.AutoSupportレポート:

HMSCSA:HA Group Notification from cluster1-03 (Health Monitor process cshm: ClusterSwitchConfig_Alert[cluster1-03]) ERROR

2.sysconfig -aの出力はポートがダウンしていることを示しています

e0b MAC Address: 00:a0:98:f1:a2:a0 (auto-unknown-fd-down) SFP Vendor: AVAGO SFP Part Number: AFBR-709SMZ-NA3 SFP Serial Number: AD184630ABF

3.システムヘルスが低下している

cluster::>system health status show
Status
---------------
degraded

 

4.Switch-Healthサブシステムが劣化しています

cluster::> system health subsystem show
Subsystem         Health
----------------- ------------------
SAS-connect       ok
Environment       ok
Memory            ok
Service-Processor ok
Switch-Health     degraded
CIFS-NDO          ok

 

  1. 次のヘルスアラートが記録されます

::> system health alert show
Node: node01
Resource: node01
Severity: Major
Indication Time: Mon Oct 07 13:19:08 2019
Suppress: false
Acknowledge: false
Probable Cause: One or more nodes are not connected to both cluster switches.
Possible Effect: If one cluster switch fails, "node01" might lose access to the cluster.
Corrective Actions: Ensure the switch "switch02" is connected to the node "node01".

Node: node01
Resource: node02
Severity: Major
Indication Time: Mon Oct 07 13:19:08 2019
Suppress: false
Acknowledge: false
Probable Cause: One or more nodes are not connected to both cluster switches.
Possible Effect: If one cluster switch fails, "node02" might lose access to the cluster.
Corrective Actions: Ensure the switch "switch01" is connected to the node "node02".

2 entries were displayed.

::> system health alert show
        Node: Node-01
      Alert ID: ClusterSwitchConnectivity_Alert
      Resource: Node01
      Severity: Major
   Indication Time: Sat Feb 17 02:00:36 2024
      Suppress: false
     Acknowledge: false
   Probable Cause: One or more nodes are not connected to both cluster switches.
   Possible Effect: If one cluster switch fails, Node01 might lose access to the cluster. 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.