ヘルスモニタプロセスcshm:SwitchPowerFail_Alert
環境
- FAS / AFF
- ONTAP 9
問題
- Notification from NodeName(ヘルスモニタプロセスcshm:SwitchPowerFail_Alert [switchname(FDxxxxxxxxx)/PowerSupply-1])アラート
- EMSログ:
[NodeName: cshmd: hm.alert.raised:alert]: Alert Id = SwitchPowerFail_Alert , Alerting Resource = switchName(FDxxxxxxxxx/PowerSupply-1 raised by monitor ethernet-switch
 [NodeName: cshmd: hm.alert.cleared:notice]: Alert Id = SwitchPowerFail_Alert , Alerting Resource = switchName(FDxxxxxxxxx)/PowerSupply-1 cleared by monitor ethernet-switch- STORAGE-FAULTASUPログ
Enclosure Status: normal
Channel: 3b
 Shelf: 0
 Shelf Type: DS224-12
 Product Serial Number: SXXXX0000000000
 Module Type: IOM12
 Power Supplies:
 Element Status         Status Bytes  Status Descriptions
   1: OK                01,00,00,A0   RQSTED ON
   2: CRITICAL          02,00,00,F3  DC FAIL, AC FAIL, OFF, RQSTED ON, FAIL