ヘルスモニターは NoStandbyLifCifsNdo_Alert により「hm.alert.raised」を発生させます
環境
- ONTAP 9
- CIFS
問題
- イベントログに表示される内容:
hm.alert.raised
例:
Tue May 29 08:09:21 2018 [node-name: nchmd: hm.alert.raised:critical]: params: {'alert_id': 'NoStandbyLifCifsNdo_Alert', 'alerting_resource': 'svm-name', 'detailed_info': 'Alert Id = NoStandbyLifCifsNdo_Alert , Alerting Resource = svm-name', 'monitor': 'node-connect'}
System health alert
表示内容:
::> system health alert show Node: node-name Resource: svm-name Severity: Minor Indication Time: Tue May 29 08:09:21 2018 Suppress: false Acknowledge: false Probable Cause: Vserver "svm-name" is actively serving data over CIFS through node "node-mame", and there are CIFS files opened persistently over continuously available shares. However, its partner node "other node-name" is not exposing any active data LIFs for the Vserver. Possible Effect: In the event that node "node-name" fails, node "other node-mame" will witness the condition very quickly. If a data LIF for Vserver "svm-name" existed on node "node-name", that node would have the capability to bring active connections away from node "other-node-name" non-disruptively and faster than waiting for the data LIF to fail over and the client to recover on its own. Corrective Actions: Create a data LIF on node "node-name" for Vserver "svm-name", or move an existing one to that node.