環境

  • ONTAP 9
  • FCP

問題

  • FC ターゲット ポート リンク - 不安定/ダウン。
  • 以下のイベントがNetAppのEMS に記録されます:

[Node1: fct_tpd_work_thread_0: scsitarget.slifct.linkBreak:error]: Link break detected on Fibre Channel target HBA 4c with event status 1 , topology type 1, status1 0x0, status2 0x0.
[Node1: fct_tpd_work_thread_0: scsitarget.hwpfct.linkUp:notice]: Link up on Fibre Channel target adapter 4c.

[Node1: fct_tpd_work_thread_0: scsitarget.slifct.wqeError:debug]: FC port 3a has a WQE processing failure of type SLI_ELS_REQ, command PLOGI, subtype x0, with status of 3 and an extended status x4 for NPIV port 0. 
[Node1: fct_tpd_work_thread_0: scsitarget.slifct.wqeError:debug]: FC port 3a has a WQE processing failure of type SLI_ELS_REQ, command PLOGI, subtype x0, with status of 3 and an extended status x1a for NPIV port 0.
[Node1: fct_tpd_work_thread_0: scsitarget.slifct.linkBreak:error]: Link break detected on Fibre Channel target HBA 3a with event status 1 , topology type 1, status1 0x0, status2 0x0. 
[Node1: fct_tpd_work_thread_0: scsitarget.slifct.wqeError:debug]: FC port 3a has a WQE processing failure of type SLI_ELS_REQ, command PLOGI, subtype x0, with status of 3 and an extended status x1a for NPIV port 0."


  • 問題を特定するには、以下の手順に従ってください:
    • コントローラ ポートのステータスでTx値が正常であることを確認し、Tx信号電力が低い場合はSFPを交換してください。
    • 接続されているスイッチ ポートのSFPステータスを確認し、スイッチ ポートのTx電力が低い場合はSFPを交換してください。
    • 両方のFC側でSFP Tx電力が正常だが、いずれかの側でSFP Rx電力が低い場合は、FCケーブルを交換してください。
    • パッチ パネルが関係している場合は、リンク コンポーネントのトラブルシューティングを行ってください。
    • 両端でRx信号が低い場合は、途中にパッチ パネルがないか確認し、テスト目的で別のポートを試してください。

例:
cluster1::> fcp adapter show -node Node1 -adapter 4c -instance
(network fcp adapter show)

Node: Node1
Adapter: 4c
Description: Fibre Channel Target Adapter 4c (Emulex LPe16000 (LPe16004), rev. 13, 16G)
Physical Protocol: fibre-channel
Maximum Speed: 16
Administrative Status: up
Operational Status: online
Extended Status: ADAPTER UP
Host Port Address: b10140
Firmware Revision: 11.2.219.4
Data Link Rate (Gbit): 16
Fabric Established: true
Fabric Name: xx:xx:xx:xx:xx:xx:xx:xx
Connection Established: ptp
Is Connection Established: true
Mediatype: ptp
Configured Speed: auto
Adapter WWNN: aa:aa:aa:aa:aa:aa:aa:aa
Adapter WWPN: bb:bb:bb:bb:bb:bb:bb:bb
Switch Port: switch1:1/88
Form Factor Of Transceiver: SFP
Vendor Name Of Transceiver: EMULEX
Part Number Of Transceiver: AFBR-57F5MZ-ELX
Revision Of Transceiver:
Serial Number Of Transceiver: AC1544J02X7
FC Capabilities Of Transceiver: 4,8,16 (Gbit/sec)
Vendor OUI Of Transceiver: 00:17:6a
Wavelength In Nanometers: 850
Date Code Of Transceiver: 15:10:26
Validity Of Transceiver: true
Connector Used: LC
Encoding Used: 64B66B
Is Internally Calibrated: true
Received Optical Power: 56.2 (uWatts)
Is Received Power In Range: true
SFP Transmitted Optical Power: 610.0 (uWatts)
Is Xmit Power In Range: true

または

Received Optical Power   587.2 (uWatts)
Is Received Power In Range  true
SFP Transmitted Optical Power 794.2 (uWatts)
Is Xmit Power In Range   true

スイッチ ポート RX/TX

RX Power:   -3.8   dBm (419.50uW)
TX Power:   -0.8   dBm (823.60 uW)

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.