問題

  • NS224シェルフのシングルディスクに中規模エラーが表示されます。

Thu Sep 29 23:58:58 -0500 [fas-f3csr3c: disk_server_0: disk.ioMediumError:notice]: Medium error on disk e0c.00.0.2: op 0x28:1f0683f4:000c sector 520520692 SCSI:medium error - Unrecovered read error - If the disk is in a RAID group, the subsystem will attempt to reconstruct unreadable data (3 11 0 81) (384) Disk e0c.00.0.2 Shelf 0 Bay 2 [NETAPP   X4013S17337T6NTE NA53] S/N [S60RNE0NA00982] UID

  • NS224シェルフ内の他の複数のディスクに書き込み検証とチェックサムのエラーが表示されます。

Fri Sep 30 06:17:57 -0500 [fas-f3csr3d: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Disk device e0f.00.1.21L0: Check Condition: CDB 0x28:6282da6c:0006: Sense Data SCSI:aborted command -  (0xb - 0x90 0x2 0xfc)(9001).
Fri Sep 30 06:17:57 -0500 [fas-f3csr3d: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Disk device e0f.00.1.17L0: Check Condition: CDB 0x28:620e2e80:0040: Sense Data SCSI:aborted command -  (0xb - 0x90 0x2 0xfc)(9004).
Fri Sep 30 06:18:14 -0500 [fas-f3csr3d: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Disk device e0f.00.1.5L0: Check Condition: CDB 0x28:4f83f33f:0001: Sense Data SCSI:aborted command -  (0xb - 0x90 0x2 0xfc)(9001).

  • 書き込み検証エラーが原因でストレージアダプタがオフラインになりました:

Fri Sep 30 05:21:48 -0500 [fas-f3csr3c: disk_admin: disk.checksum.offlineAdapter:alert]: Adapter e0f taken offline due to checksum verification failure on multiple disks. Keep the adapter offline and contact Contact NetApp technical support. for assistance.
Fri Sep 30 05:21:48 -0500 [fas-f3csr3c: disk_admin: callhome.hba.failed:EMERGENCY]: Call home for Write Verification Error: Port e0f Failed. Keep the adapter offline and contact NetApp technical support for assistance.

Fri Sep 30 05:21:47 -0500 [fas-f3csr3d: disk_server_0: disk.checksum.offlineAdapter:alert]: Adapter e0c taken offline due to checksum verification failure on multiple disks. Keep the adapter offline and contact Contact NetApp technical support. for assistance.
Fri Sep 30 05:21:47 -0500 [fas-f3csr3d: disk_server_0: callhome.hba.failed:EMERGENCY]: Call home for Write Verification Error: Port e0c Failed. Keep the adapter offline and contact NetApp technical support for assistance.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.