スイッチに接続されたNS224シェルフからMixedDomainFromNodeToSwitch_Alertが表示される
環境
- ONTAP 9
- スイッチ接続型ストレージ
- NS224シェルフ
問題
- ノードのリブート後にMixedDomainFromNodeToSwitchヘルスアラートが報告される
- スイッチ接続のNS224シェルフでマルチパスが報告される
-
MixedDomainFromSwitchToShelf_Alert
メッセージ:[node_name: schmd: hm.alert.raised:alert]: Alert Id = MixedDomainFromSwitchToShelf_Alert , Alerting Resource = switch_name-a(ABC123456D7) raised by monitor system-connect
[node_name: schmd: hm.alert.raised:alert]: Alert Id = MixedDomainFromSwitchToShelf_Alert , Alerting Resource = switch_name-b(ABC123456D8) raised by monitor system-connect
System health alert
:
::> system health alert show
Node: node_name
Alert ID: MixedDomainFromSwitchToShelf_Alert
Resource: Switch name: switch_name-a(ABC123456D7)
Severity: Minor
Indication Time: Tue Jan 10 12:10:02 2023
Suppress: false
Acknowledge: false
Probable Cause: Storage Switch switch_name-a is connected to shelves 3.20,
3.30 with mixed domains.
Possible Effect: This issue will affect conversions to direct-attached
storage.
Corrective Actions: Connect the switch node_name to both shelves with the
same storage domain, following the guide applicable to
your shelf.
Node: node_name
Alert ID: MixedDomainFromSwitchToShelf_Alert
Resource: Switch name: switch_name-b(ABC123456D8)
Severity: Minor
Indication Time: Tue Jan 10 12:10:02 2023
Suppress: false
Acknowledge: false
Probable Cause: Storage Switch switch_name-b is connected to shelves 3.20,
3.30 with mixed domains.
Possible Effect: This issue will affect conversions to direct-attached
storage.
Corrective Actions: Connect the switch node_name to both shelves with the
same storage domain, following the guide applicable to
your shelf.
2 entries were displayed.system health subsystem show
SAS-connect_Cluster degraded
システム再起動後の「」 の例:
::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
...
FHM-Bridge ok
SAS-connect_Cluster degraded
13 entries were displayed.::*> system health subsystem show -instance -subsystem SAS-connect_Cluster
Subsystem: SAS-connect_Cluster
Health: unknown
Initialization State: start_discovery
Number of Outstanding Alerts: 0
Number of Suppressed Alerts: 0
Node: node_name
Subsystem Refresh Interval: 30m