環境

  • All FASシステム
  • All AFFシステム

問題

  • 問題またはディスクスタックとの通信が失われる
  • EMSで次の情報が報告されます。
Mon Oct 11 07:58:05 -0600 [node-01: dsa_disc: ses.multipath.ReqError:alert]: SAS disk shelf detected without a multipath configuration.
  • [sysconfig -a]で、一方または両方のノードが混在パス構成を報告している
 NetApp Release 9.7P9: Thu Nov 5 20:15:56 EST 2020 System ID: 0XXXXXXXXX (node-01); partner ID: 0XXXXXXXXX (node-02) System Serial Number: XXXXXXXXXXXXXX (node-01) System Rev: C1 System Storage Configuration: Mixed-Path 
  • SASポートは無効になっていますが、ケーブルが接続されています
     slot 2: SAS Host Adapter 2b (PMC-Sierra PM8001 rev. C, SAS, <OFFLINE (soft)>) MFG Part Number: USI 6086-000010-07 rev. MP V4.13 Part number: 111-00341+G1 Serial number: xxxxxxxxxxx Date Code: 20150817 Firmware rev: 01.12.09.00 Base WWN: 5:00e004:xxxxxxx:xx Phy State: [4] Disabled [5] Disabled [6] Disabled [7] Disabled QSFP Vendor: Amphenol QSFP Part Number: X6558-R6+A0 QSFP Type: Passive Copper 2m ID:00 QSFP Serial Number: xxxxxxxxxxxxxx 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.