メインコンテンツへスキップ

複数のセンサーがLNCとLCRを示す

Views:
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
HW
Last Updated:

適用対象

  • ONTAP 9

問題

  • AutoSupportから、SPの異常リブートが繰り返し報告され、最終的にテイクオーバーが発生しました。
System Alert from SP of node1 (REBOOT (abnormal)) WARNING複数のセンサーがcr、LNC、LCRのステータスをSP-LATEST-IPMIで示しています。

======================================
hsamcmd --fault-show-all
===============================
tag  origin  fld                    fault reason                   count  time           
---- ------- ----                   -------------                   ------ -----         
1   bmc    /chassis-1/controller-a         P3V3: Voltage Sensor 25 LNC           1    Thu Aug 15 05:26:35 2024
2   bmc    /chassis-1/controller-a         P3V3: Voltage Sensor 25 LCR           1    Thu Aug 15 05:26:36 2024
3   bmc    /chassis-1/controller-a         P12V: Voltage Sensor 32 LNC           1    Thu Aug 15 05:26:36 2024
4   bmc    /chassis-1/controller-a         P12V: Voltage Sensor 32 LCR           1    Thu Aug 15 05:26:36 2024
5   bmc    /chassis-1/controller-a         P12V_Curr: Current Sensor 34 LNC        1    Thu Aug 15 05:26:36 2024
6   bmc    /chassis-1/controller-a         P12V_Curr: Current Sensor 34 LCR        1    Thu Aug 15 05:26:36 2024

 

P3V3             | 0.000      | Volts      | cr        | 2.958     | 3.028     | 3.570     | 3.658     
P3V3_BATT        | 2.888      | Volts      | ok         | 2.100     | 2.205     | 3.395     | 3.500     
P3V3_STBY        | 3.290      | Volts      | ok         | 2.958     | 3.028     | 3.570     | 3.658     
P1V15_STBY       | 1.157      | Volts      | ok         | 1.030     | 1.051     | 1.250     | 1.342     
Power_Good       | 0x0        | discrete   | Deasserted | na        | na        | na        | na        
Power_Proc_OK    | 0x0        | discrete   | Asserted   | na        | na        | na        | na        
P12V             | 0.186      | Volts      | cr        | 10.540    | 10.850    | 12.958    | 13.454    
P12V_STBY        | 11.966     | Volts      | ok         | 10.540    | 10.850    | 12.958    | 13.454    
P12V_Curr        | 0.000      | Amps       | cr        | 0.000     | 0.000     | 15.810    | 15.810 

  • BMCファームウェアの バージョンが 最新です。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.