メインコンテンツへスキップ

LEDが点灯し、ハードウェア障害が表示されないNS224ドライブ

Views:
Visibility:
Public
Votes:
0
Category:
not set
Specialty:
hw
Last Updated:

環境

 

  • AFF-A400
  • NS224

問題

  • 一部のドライブのLEDが点灯し、ハードウェア障害は確認できない。
  • psmadmin inband_cli 0X.0.A "report_faults".0.A は、LEDライトが点灯しているドライブに障害があることを報告します。 

::*> system node run -node A -command psmadmin inband_cli 0X.0.A "report_faults"
----------------------------------------------------------------------
Drive Manager faults
Drive 1 faults: SES set fault;
Drive 3 faults: SES set fault;

シェルフのログを見ると、LEDのオンとオフが切り替わっていることがわかります。  


Shelflog start time: Fri Oct 6 03:31:03 GMT 2023
Controller Id: 538222273
Channel: 0x Shelf: 0 Module type: NSM100 Firmware rev: 0203
Shelf product id: NS224NSM100
Shelf Serial Number: SHFGB2106000042
Module A Serial Number: 042041031202
Log ID: SHFGB2106000042_A_0
Timestamp: Sun Dec 8 01:00:11 UTC 2024
--------------------------------------------------------------
EVENT LOGS
Timestamp Sun Dec 8 01:00:11 2024
(1047+09:03:36.189)
Sun Dec 8 01:00:03 2024 ( 1047+09:03:28.875); 030D005F; M0; ENC_MGT; ses; 02; SES requested FAULT led OFF for drive 1
Sun Dec 8 01:00:03 2024 ( 1047+09:03:28.875); 030D005F; M0; ENC_MGT; ses; 02; SES requested FAULT led OFF for drive 3
Sun Dec 8 01:00:03 2024 ( 1047+09:03:28.875); 03030162; M0; ENC_MGT; drive_manager; 02; Drive fault state changed through SES on drive 1(changed faultState = 0x0)
Sun Dec 8 01:00:03 2024 ( 1047+09:03:28.875); 03030162; M0; ENC_MGT; drive_manager; 02; Drive fault state changed through SES on drive 3(changed faultState = 0x0)
Sun Dec 8 01:00:05 2024 ( 1047+09:03:30.274); 030D005E; M0; ENC_MGT; ses; 02; SES requested FAULT led ON for drive 1
Sun Dec 8 01:00:05 2024 ( 1047+09:03:30.274); 030D005E; M0; ENC_MGT; ses; 02; SES requested FAULT led ON for drive 3
Sun Dec 8 01:00:05 2024 ( 1047+09:03:30.274); 03030162; M0; ENC_MGT; drive_manager; 02; Drive fault state changed through SES on drive 1(changed faultState = 0x1)
Sun Dec 8 01:00:05 2024 ( 1047+09:03:30.274); 03030162; M0; ENC_MGT; drive_manager; 02; Drive fault state changed through SES on drive 3(changed faultState = 0x1)

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • この記事は役に立ちましたか?