NSM100 で複数の環境エラーが検出されました
環境
- ONTAP 9
- NS224
- NSM100
問題
- 1つのNSM100モジュールについて報告されたエラー:
::*> storage shelf show -errors Shelf Name: 1.12 Serial Number: XXXXXXXXXXXXXXX Error Type Description ------------------ --------------------------- Bootdevice Boot device "2" error detected. Coinbattery Coin cell battery "2" error detected. DIMM DIMM "5" error detected. DIMM is located in the DIMM slot 1 in the bottom shelf module (B). DIMM DIMM "6" error detected. DIMM is located in the DIMM slot 2 in the bottom shelf module (B). DIMM DIMM "7" error detected. DIMM is located in the DIMM slot 3 in the bottom shelf module (B). DIMM DIMM "8" error detected. DIMM is located in the DIMM slot 4 in the bottom shelf module (B). Fan Error detected in cooling fan "11". Fan is located in the inlet FAN of fan module 1 in the bottom shelf module (B). Fan Error detected in cooling fan "12". Fan is located in the inlet FAN of fan module 2 in the bottom shelf module (B). Fan Error detected in cooling fan "13". Fan is located in the inlet FAN of fan module 3 in the bottom shelf module (B). Fan Error detected in cooling fan "14". Fan is located in the inlet FAN of fan module 4 in the bottom shelf module (B). Fan Error detected in cooling fan "15". Fan is located in the inlet FAN of fan module 5 in the bottom shelf module (B). Fan Error detected in cooling fan "16". Fan is located in the outlet FAN of fan module 1 in the bottom shelf module (B). Fan Error detected in cooling fan "17". Fan is located in the outlet FAN of fan module 2 in the bottom shelf module (B). Fan Error detected in cooling fan "18". Fan is located in the outlet FAN of fan module 3 in the bottom shelf module (B). Fan Error detected in cooling fan "19". Fan is located in the outlet FAN of fan module 4 in the bottom shelf module (B). Fan Error detected in cooling fan "20". Fan is located in the outlet FAN of fan module 5 in the bottom shelf module (B). Module Critical error detected in module "B". Power Critical condition is detected in storage shelf power supply unit "2". The unit might fail. Temperature Temperature reported by temperature sensor "12" exceeds the specifications for the disk shelf or its components. Temperature Temperature reported by temperature sensor "13" exceeds the specifications for the disk shelf or its components. Temperature Temperature reported by temperature sensor "14" exceeds the specifications for the disk shelf or its components. Temperature Temperature reported by temperature sensor "15" exceeds the specifications for the disk shelf or its components. Temperature Temperature reported by temperature sensor "16" exceeds the specifications for the disk shelf or its components. Temperature Temperature reported by temperature sensor "17" exceeds the specifications for the disk shelf or its components.
- シェルフ ファームウェアを最新バージョンにアップグレードしても問題が解決しない。
- NSM100 Bのリブート、再装着、交換の後も問題は解決しない。