メインコンテンツへスキップ

FAS8300/FAS8700/AFF A400システムのNVRAMバッテリ低下アラート

Views:
210
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
HW
Last Updated:

環境

  • AFF A400
  • FAS8300
  • FAS8700
  • BMC 13.11P1 以降

問題

  • BATTERY (capacity low) AutoSupportメール送信済み。
  • ONTAPイベントメッセージ(EMS-LOG-FILE)例:

ERROR nvmem.battery.chgrFailed: The NVMEM battery charger is disabled because a bad charger circuit is detected.....
ALERT monitor.shutdown.nvramLowBattery.pending: NVRAM battery is dangerously low. Halting system in 24 hours. Replace the battery immediately!
ALERT callhome.battery.low: Call home for BATTERY_LOW.
EMERGENCY monitor.nvramLowBattery: NVRAM battery is dangerously low.
ERROR nvmem.battery.capLowWarn: The NVMEM battery capacity is below normal (4 cycles).

ALERT monitor.shutdown.nvramLowBattery.pending:  NVRAM battery is dangerously low. Halting system in 23 hours. Replace the battery immediately!
  • NVMEMバッテリー容量が正常値を下回っています。例:
::*> system node environment sensors show -name "Bat Curr"|"Bat Dstg Cycles"
Node Sensor                 State   Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------   ----------- -------- -------- ------- -------
Node01
     Bat Curr              normal   0 mA        -        -        1225    1475
     Bat Dstg Cycles       warn-low 4 cycles    2        5        -       -
Node02
     Bat Curr              normal   0 mA        -        -        1225    1475
     Bat Dstg Cycles       normal   14 cycles   2        5        -       -
  •  SP-LATEST-STATISTICS AutoSupportセクションで報告されたRelativeChargeの低下。例:

Tue Jul 08, 2025 00:27:02 +0530
    RelativeCharge    : 21 %
Tue Jul 08, 2025 13:13:18 +0530
    RelativeCharge    : 21 %
Wed Jul 09, 2025 00:17:03 +0530
    RelativeCharge    : 19 %
Wed Jul 09, 2025 13:13:18 +0530
    RelativeCharge    : 19 %
Thu Jul 10, 2025 00:37:04 +0530
    RelativeCharge    : 18 %
Thu Jul 10, 2025 13:13:18 +0530
    RelativeCharge    : 18 %

  • BMCからのsystem battery showの表示:
  • Currentフィールドに 0 mAと表示されます。
  • RelativeChargeフィールドに71%未満と表示されます。
  • ChargingCurrentフィールドに 1000 mAと表示されます。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.