メインコンテンツへスキップ

FAS8300/FAS8700システムのNVRAMバッテリ低下アラート

Views:
2
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
HW
Last Updated:

環境

  • AFF A400
  • FAS8300
  • FAS8700
  • ONTAP9.15.1P7
  • BMC 13.11P1

問題

  • EMSイベントは、NVRAMバッテリが危険なほど残量が少なく、24時間以内にシステムが停止する可能性があることを示す複数のアラートを報告します。
ALERT monitor.shutdown.nvramLowBattery.pending: NVRAM battery is dangerously low. Halting system in 24 hours. Replace the battery immediately!
ALERT callhome.battery.low: Call home for BATTERY_LOW.
EMERGENCY monitor.nvramLowBattery: NVRAM battery is dangerously low.
ERROR nvmem.battery.capLowWarn: The NVMEM battery capacity is below normal (4 cycles).
ALERT monitor.shutdown.nvramLowBattery.pending:  NVRAM battery is dangerously low. Halting system in 23 hours. Replace the battery immediately!
  • NVMEMバッテリ容量が正常値未満です(4サイクル)。
::*> system node environment sensors show -name "Bat Curr"|"Bat Dstg Cycles"
Node Sensor          State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------ ----------- -------- -------- ------- -------
Node01
   Bat Curr        normal
                     0 mA      -     -   1225   1475
   Bat Dstg Cycles     warn-low
                    4 cycles   2     5     -     -
Node02
   Bat Curr        normal
                     0 mA      -     -   1225   1475
   Bat Dstg Cycles     normal
                    14 cycles    2     5     -     -
  • SP-LATEST-STATISTICSは相対電荷の低下を示します

=-=-=-=-=-= Tue Jul 08, 2025 00:27:02 +0530  SP-LATEST-STATISTICS 1 line
   RelativeCharge   : 21 %
=-=-=-=-=-= Tue Jul 08, 2025 13:13:18 +0530  SP-LATEST-STATISTICS 1 line
   RelativeCharge   : 21 %
=-=-=-=-=-= Wed Jul 09, 2025 00:17:03 +0530  SP-LATEST-STATISTICS 1 line
   RelativeCharge   : 19 %
=-=-=-=-=-= Wed Jul 09, 2025 13:13:18 +0530  SP-LATEST-STATISTICS 1 line
   RelativeCharge   : 19 %
=-=-=-=-=-= Thu Jul 10, 2025 00:37:04 +0530  SP-LATEST-STATISTICS 1 line
   RelativeCharge   : 18 %
=-=-=-=-=-= Thu Jul 10, 2025 13:13:18 +0530  SP-LATEST-STATISTICS 1 line
   RelativeCharge   : 18 %

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.