SP HBT Stoppedアラートが原因でノードが停止します
環境
- AFF-A300
- FAS8200
- FAS8700
- FAS2720
- FAS2620
- ONTAP 9
問題
- ノードが停止し、イベントログに次のエラーが記録されます。
[Node-02: spsm_listener: sp.heartbeat.stopped:error]: Have not received a IPMI heartbeat from the Service Processor (SP) in last 20 seconds.
[Node-02: spsm_listener: callhome.sp.hbt.missed:notice]: Call home for SP HBT MISSED
[Node-02: env_mgr: sp.ipmi.lost.shutdown:EMERGENCY]: SP heartbeat stopped and cannot be recovered. To prevent hardware damage and data loss, the system will shut down in 2 minutes.
[Node-02: spsm_listener: callhome.sp.hbt.stopped:alert]: Call home for SP HBT STOPPED
- ノードがダウンする前に、
SP-LATEST-IPMI
複数のセンサーが正常に読み取れないことが報告される場合があります:
Sensor Name State Current Critical Warning Warning Critical
Reading Low Low High High
-------------------------------------------------------------------------------------------------
Partner Status not_available --
PSU1 Present not_available --
PSU1 5V not_available -- mV -- -- -- --
PSU1 12V not_available -- mV -- -- -- --
PSU1 5V Curr not_available -- mA -- -- -- --
PSU1 12V Curr not_available -- mA -- -- -- --
PSU1 Fan 1 not_available -- RPM -- -- -- --
PSU1 Fan 2 not_available -- RPM -- -- -- --
PSU1 Inlet Temp not_available -- C 0 C 5 C 57 C 62 C
PSU1 Hotspot Temp not_available -- C 0 C 5 C 90 C 100 C
PSU2 Present not_available --
PSU2 5V not_available -- mV -- -- -- --
PSU2 12V not_available -- mV -- -- -- --
PSU2 5V Curr not_available -- mA -- -- -- --
PSU2 12V Curr not_available -- mA -- -- -- --
PSU2 Fan 1 not_available -- RPM -- -- -- --
PSU2 Fan 2 not_available -- RPM -- -- -- --
PSU2 Inlet Temp not_available -- C 0 C 5 C 57 C 62 C
PSU2 Hotspot Temp not_available -- C 0 C 5 C 90 C 100 C
PSU_FAN not_available --
Module B Expander Temp failed -- C 0 C 5 C 80 C 90 C
Module A Expander Temp failed -- C 0 C 5 C 80 C 90 C
Midplane 4 Temp failed -- C 0 C 5 C 47 C 52 C
Midplane 3 Temp failed -- C 0 C 5 C 47 C 52 C
Midplane 2 Temp failed -- C 0 C 5 C 47 C 52 C
Midplane 1 Temp failed -- C 0 C 5 C 47 C 52 C
Ambient Temp failed -- C 0 C 5 C 47 C 50 C
Internal Shelf not_available --
- 電源を再投入して再装着したあともノードをブートできない。