メインコンテンツへスキップ

SP HBT Stoppedアラートが原因でノードが停止します

Views:
15
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
HW
Last Updated:

環境

  • AFF-A300
  • FAS8200
  • FAS8700
  • FAS2720
  • FAS2620
  • ONTAP 9

問題

  • ノードが停止し、イベントログに次のエラーが記録されます。

[Node-02: spsm_listener: sp.heartbeat.stopped:error]: Have not received a IPMI heartbeat from the Service Processor (SP) in last 20 seconds.
[Node-02: spsm_listener: callhome.sp.hbt.missed:notice]: Call home for SP HBT MISSED
[Node-02: env_mgr: sp.ipmi.lost.shutdown:EMERGENCY]: SP heartbeat stopped and cannot be recovered. To prevent hardware damage and data loss, the system will shut down in 2 minutes.
[Node-02: spsm_listener: callhome.sp.hbt.stopped:alert]: Call home for SP HBT STOPPED

  • ノードがダウンする前に、SP-LATEST-IPMI複数のセンサーが正常に読み取れないことが報告される場合があります:

Sensor Name        State      Current   Critical    Warning    Warning   Critical
                     Reading     Low      Low      High     High
-------------------------------------------------------------------------------------------------
Partner Status       not_available    --
PSU1 Present        not_available    --
PSU1 5V          not_available    -- mV     --      --      --      --
PSU1 12V          not_available    -- mV     --      --      --      --
PSU1 5V Curr        not_available    -- mA     --      --      --      --
PSU1 12V Curr       not_available    -- mA     --      --      --      --
PSU1 Fan 1         not_available    -- RPM    --      --      --      --
PSU1 Fan 2         not_available    -- RPM    --      --      --      --
PSU1 Inlet Temp      not_available    -- C      0 C      5 C     57 C     62 C
PSU1 Hotspot Temp     not_available    -- C      0 C      5 C     90 C     100 C
PSU2 Present        not_available    --
PSU2 5V          not_available    -- mV     --      --      --      --
PSU2 12V          not_available    -- mV     --      --      --      --
PSU2 5V Curr        not_available    -- mA     --      --      --      --
PSU2 12V Curr       not_available    -- mA     --      --      --      --
PSU2 Fan 1         not_available    -- RPM    --      --      --      --
PSU2 Fan 2         not_available    -- RPM    --      --      --      --
PSU2 Inlet Temp      not_available    -- C      0 C      5 C     57 C     62 C
PSU2 Hotspot Temp     not_available    -- C      0 C      5 C     90 C     100 C
PSU_FAN          not_available    --
Module B Expander Temp   failed       -- C      0 C      5 C     80 C     90 C
Module A Expander Temp   failed       -- C      0 C      5 C     80 C     90 C
Midplane 4 Temp      failed       -- C      0 C      5 C     47 C     52 C
Midplane 3 Temp      failed       -- C      0 C      5 C     47 C     52 C
Midplane 2 Temp      failed       -- C      0 C      5 C     47 C     52 C
Midplane 1 Temp      failed       -- C      0 C      5 C     47 C     52 C
Ambient Temp        failed       -- C      0 C      5 C     47 C     50 C
Internal Shelf       not_available    --

  • 電源を再投入して再装着したあともノードをブートできない。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.