DualControllerNonHa_Alert通知でノードが応答しません
環境
- FAS8200
- ONTAP 9.11.1P2
問題
- ノードが応答していません
- 複数シェルフのEMSアラート:
[node_name-02: schmd: hm.alert.raised:alert]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:37:f4:f9 raised by monitor system-connect
[node_name-02: schmd: hm.alert.raised:alert]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:37:f5:19 raised by monitor system-connect
[node_name-02: schmd: hm.alert.raised:alert]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:37:f7:2c raised by monitor system-connect
[node_name-02: schmd: hm.alert.raised:alert]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:37:ff:c0 raised by monitor system-connect
[node_name-02: schmd: hm.alert.raised:alert]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:38:8c:6c raised by monitor system-connect
[node_name-02: schmd: hm.alert.raised:alert]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:38:8f:50 raised by monitor system-connect
[node_name-02: schmd: hm.alert.raised:alert]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:0b:32:aa:47 raised by monitor system-connect
[node_name-02: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: DualControllerNonHa_Alert[50:0a:09:80:08:37:f4:f9].
- 健全性アラートのレポート:
Monitor system-connect
Alert ID DualControllerNonHa_Alert
Subsystem SAS-connect_Cluster
Probable Cause Configuration_error
Description
Storage shelf 22 is connected to two controllers (node_name-02, node_name-01) that are not an HA pair.
Storage shelf 21 is connected to two controllers (node_name-02, node_name-01) that are not an HA pair.
Storage shelf 23 is connected to two controllers (node_name-02, node_name-01) that are not an HA pair.
Storage shelf 13 is connected to two controllers (node_name-02, node_name-01) that are not an HA pair.
Storage shelf 11 is connected to two controllers (node_name-02, node_name-01) that are not an HA pair.
Storage shelf 20 is connected to two controllers (node_name-02, node_name-01) that are not an HA pair.
Storage shelf 10 is connected to two controllers (node_name-02, node_name-01) that are not an HA pair.
- ノードのリブート後にアラートがクリアされました:
[node_name-02: schmd: hm.alert.cleared:notice]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:37:f4:f9 cleared by monitor system-connect
[node_name-02: schmd: hm.alert.cleared:notice]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:37:f5:19 cleared by monitor system-connect
[node_name-02: schmd: hm.alert.cleared:notice]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:37:f7:2c cleared by monitor system-connect
[node_name-02: schmd: hm.alert.cleared:notice]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:37:ff:c0 cleared by monitor system-connect
[node_name-02: schmd: hm.alert.cleared:notice]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:38:8c:6c cleared by monitor system-connect
[node_name-02: schmd: hm.alert.cleared:notice]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:08:38:8f:50 cleared by monitor system-connect
[node_name-02: schmd: hm.alert.cleared:notice]: Alert Id = DualControllerNonHa_Alert , Alerting Resource = 50:0a:09:80:0b:32:aa:47 cleared by monitor system-connect