メインコンテンツへスキップ

バッテリ センサーが読み取り不能であることによるノードのシャットダウン

Views:
24
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

環境

  • ONTAP 9
  • BMC
  • バッテリ

問題

  • ノードで突然環境シャットダウンが実行される。EMSログでは次の情報を確認できます:

XXX XX XX:XX:XX [Cluster1:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Curr' unreadable) CRITICAL.
XXX XX XX:XX:XX [Cluster1:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Charge Curr' unreadable) CRITICAL.
XXX XX XX:XX:XX [Cluster1:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Initial FCC' unreadable) CRITICAL.
XXX XX XX:XX:XX [Cluster1:nvmem.battery.packInvalid:EMERGENCY]: The incorrect NVMEM battery is installed. Expected part number is 271-00045. To prevent data loss, the system will shut down in 5 minutes.
XXX XX XX:XX:XX [Cluster1:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Volt' unreadable) CRITICAL.
XXX XX XX:XX:XX [Cluster1:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Full Cap' unreadable) CRITICAL.
XXX XX XX:XX:XX [Cluster1:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Charge Volt' unreadable) CRITICAL.
XXX XX XX:XX:XX [Cluster1:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Dstg Cycles' unreadable) CRITICAL.
XXX XX XX:XX:XX [Cluster1:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Dcharge FET' unreadable) CRITICAL.
XXX XX XX:XX:XX [Cluster1:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Charge FET' unreadable) CRITICAL.
XXX XX XX:XX:XX [Cluster1:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery current critical)

  • 読み取り不能なセンサーからBMCが回復されました

Record 338: Sat Nov 08 00:11:11.149382 2025 [IPMI.warning]: Recovering BMC due to a non-readable sensor

  • バッテリー学習サイクルの開始と失敗が確認されます

Record 409: Sat Nov 08 12:05:11.263893 2025 [IPMI.notice]: 0416 | 02 | EVT: 6f06ffff | Bat_Status | Assertion Event, "Learn Cycle"
Record 410: Sat Nov 08 15:17:02.842815 2025 [BMC.notice]: Battery Learning cycle failed with error 0x88
Record 411: Sat Nov 08 15:17:13.542179 2025 [IPMI.notice]: 0417 | 02 | EVT: ef06ffff | Bat_Status | Deassertion Event, "Learn Cycle"

  • 次に、NVMEMバッテリの読み取り不能センサーのアラートが原因でノードがリブートします

Record 468: Sun Nov 09 00:12:49.406520 2025 [IPMI.emergency]: env_mgr triggers OS halt:Battery temp unreadable for 2 mins
Record 469: Sun Nov 09 00:13:23.584592 2025 [Controller.notice]: Appliance user command halt.
Record 470: Sun Nov 09 00:13:23.624175 2025 [IPMI.notice]: 0451 | 02 | EVT: 6f03ffff | Sensor 255 | Assertion Event, "Storage OS graceful shutdown"
Record 471: Sun Nov 09 00:13:25.340475 2025 [IPMI Event.critical]: System power down
Record 472: Sun Nov 09 00:13:25.344857 2025 [IPMI.emergency]: Data ONTAP initiated shutdown

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.