メインコンテンツへスキップ

ノードのテイクオーバーとバッテリーセンサーがBMCでnot_availableと表示される

Views:
3
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

環境

  • ONTAP 9
  • AFF C60

問題

  • 多くのセンサーがnot_availableBMCでノードがテイクオーバー状態になります。
  • ノードはpingに応答しません。
  • 次のようなEMSメッセージが表示される場合があります。

Thu May 15 08:08:45 +0000 [Node: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Full Cap' sensor is unreadable. To prevent data loss, the system will shut down in 20 minutes.
Thu May 15 08:08:45 +0000 [Node: env_mgr: nvmem.battery.unreadHrs:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Charge Curr' sensor is unreadable. To prevent data loss, the system will shut down in in 24 hours.
Thu May 15 08:08:55 +0000 [Node: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Design Cap' sensor is unreadable. To prevent data loss, the system will shut down in 20 minutes.
Thu May 15 08:09:15 +0000 [Node: env_mgr: nvmem.battery.unreadHrs:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Charge Volt' sensor is unreadable. To prevent data loss, the system will shut down in in 24 hours.
Thu May 15 08:09:16 +0000 [Node: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Dstg Cycles' sensor is unreadable. To prevent data loss, the system will shut down in 20 minutes.

  • ノードの乗っ取り前に多くのバッテリーセンサーが表示not_available

Bat Status        normal       1      --      --      --      --
Bat Present               PRESENT
Bat Dcharge FET               ON
Bat Charge FET                ON
Bat Pack Invalid               OK
Bat Learning Active             OFF
Bat Temp         not_available   -- C     -5 C     0 C     55 C     60 C
Bat Volt         not_available   -- mV   5500 mV   5750 mV   8300 mV   8500 mV
Bat Curr         not_available   -- mA   -26910 mA   -25990 mA   1150 mA   1380 mA
Bat Rem Cap        not_available   -- W*hr  2550 W*hr  3000 W*hr  17475 W*hr  18000 W*hr
Bat Full Cap       not_available   -- W*hr  5775 W*hr  6000 W*hr  17475 W*hr  18000 W*hr
Bat Charging State    invalid       --
Bat Pct Capacity     invalid      -- %     39 %     44 %     --      --
Bat Charge Curr      not_available   -- mA    --      --      --      --
Bat Charge Volt      not_available   -- mV   6000 mV   6200 mV   8400 mV   8600 mV
Bat Design Cap      not_available   -- W*hr   --      --      --      --
Bat Dstg Cycles      not_available   -- cycles   2 cycles   3 cycles  --      --
Bat Cycle Count      not_available   -- cycles  --      --      --     450 cycles
Bat FRU LED        invalid       --
Battery Charge Failed?  invalid       --
Battery Charge Bad?    invalid       --
Battery Capacity Message          GOOD

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.