ONTAP が callhome.dsk.redun.fault イベントを報告します
環境
- DS212-12
- IOM12
- X336_TTCRE04TA07
問題
- イベントログには、callhome.dsk.redun.fault: Call home for DISK REDUNDANCY FAILEDと表示されています。
Node: node1Sequence#: 583106Time: 4/9/2026 01:58:33Severity: ERRORSource: dsa_discMessage Name: callhome.dsk.redun.faultEvent: callhome.dsk.redun.fault: Call home for DISK REDUNDANCY FAILEDCorrective Action: Locate disks which have lost redundancy by using the following command: "storage disk show -fields disk,primary-port,secondary-name,secondary-port,shelf,bay" Note all channels with single path connectivity. Check for failures using these commands: "system health node-connectivity shelf show" and "system health system-connectivity shelf show". If a module or cable failure is identified, replace the failed module or cable. Confirm redundancy has been restored with the following command: "storage disk show -fields disk,primary-port,secondary-name,secondary-port,shelf,bay" If you need assistance, contact NetApp technical support.Description: This message occurs when redundant access to disk storage is lost. This message and associated Autosupport are issued at most once per day. If your system is configured to do so, it generates and transmits an AutoSupport (or 'call home') message to NetApp technical support and to the configured destinations. Successful delivery of an AutoSupport message significantly improves problem determination and resolution.
- システム警告LEDが点灯しています
- ディスク2.11.4は、他のディスクに比べてパスの数が少なく、期待される冗長パスは表示されません
cluster::> storage disk show -disk 2.11.4 -instance Disk: 2.11.4 Container Type: aggregate Owner/Home: node2 / node2 DR Home: - Stack ID/Shelf/Bay: 2 / 11 / 4 LUN: 0 Array: N/A Vendor: NETAPP Model: X336_TTCRE04TA07 Serial Number: xxxxxx93F9XC UID: xxxxxxxx:xxxxxxxxx BPS: 520 Physical Size: 3.64TB Position: dataChecksum Compatibility: block Aggregate: node2_aggr02 Plex: plex0Paths: LUN Initiator Side Target Side LinkController Initiator ID Switch Port Switch Port Acc Use Target Port TPGN Speed I/O KB/s IOPS------------------ --------- ----- -------------------- -------------------- --- --- ----------------------- ------ ------- ------------ ------------node2 2a 0 N/A N/A AO INU xxxxxxxxxxxxd2a9 48 12 Gb/S 132 1node1 0d 0 N/A N/A AO INU xxxxxxxxxxxxd2a9 48 12 Gb/S 0 0 Errors:-
cluster::> storage disk show -disk 2.11.3 -instance Disk: 2.11.3 Container Type: aggregate Owner/Home: node2 / node2 DR Home: - Stack ID/Shelf/Bay: 2 / 11 / 3 LUN: 0 Array: N/A Vendor: NETAPP Model: X336_TTCRE04TA07 Serial Number: xxxxxx95F9XC UID: xxxxxxxx:xxxxxxxx BPS: 520 Physical Size: 3.64TB Position: dataChecksum Compatibility: block Aggregate: node2_aggr02 Plex: plex0Paths: LUN Initiator Side Target Side LinkController Initiator ID Switch Port Switch Port Acc Use Target Port TPGN Speed I/O KB/s IOPS------------------ --------- ----- -------------------- -------------------- --- --- ----------------------- ------ ------- ------------ ------------node2 0d 0 N/A N/A AO INU xxxxxxxxxxxxd2c6 56 12 Gb/S 0 0node2 2a 0 N/A N/A AO RDY xxxxxxxxxxxxd2c5 25 12 Gb/S 0 0node1 0d 0 N/A N/A AO INU xxxxxxxxxxxxd2c5 25 12 Gb/S 0 0node1 2a 0 N/A N/A AO RDY xxxxxxxxxxxxd2c6 56 12 Gb/S 0 0 Errors:-
- ディスク 2.11.4 が sysconfig -a に表示されません
node1
slot 2: SAS Host Adapter 2a (Broadcom SAS3616W rev. 2, SAS, <UP>) Firmware rev: 17.00.00.00 NVDATA rev: 17.01.00.11 Base WWN: xxxxxxxxxxxxxxxxx Temperature: Not Available MFG Part Number: 111-04226 Board Name: HBA 9405W-16e Assembly: 03-50044-10006 Serial number: xxxxxxxxx Phy State: [0] Enabled, 12.0 Gb/s [1] Enabled, 12.0 Gb/s [2] Enabled, 12.0 Gb/s [3] Enabled, 12.0 Gb/s Mini-SAS HD Vendor: Amphenol Mini-SAS HD Part Number: 112-00437+A0 Mini-SAS HD Type: Passive Copper (unequalized) 2m end_1 Mini-SAS HD Serial Number: xxxxxxxxx00664 11.0 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx97F9XC) 11.1 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx5F9XC) 11.2 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxxB8F9XC) 11.3 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx95F9XC) 11.5 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx98F9XC) 11.6 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx9TF9XC) 11.7 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxxB0F9XC) 11.8 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx9NF9XC) 11.9 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx9GF9XC) 11.10: NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx9JF9XC) 11.11: NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx99F9XC) Shelf 11: DS212-12 Firmware rev. IOM12 A: 0281 IOM12 B: 0281
node2
slot 0: SAS Host Adapter 0d (Broadcom SAS3616W rev. 2, SAS, <UP>) Firmware rev: 12.00.00.00 NVDATA rev: 12.03.01.02 Base WWN: xxxxxxxxxxxxxxxxx Temperature: Not Available Phy State: [0] Enabled, 12.0 Gb/s [1] Enabled, 12.0 Gb/s [2] Enabled, 12.0 Gb/s [3] Enabled, 12.0 Gb/s Mini-SAS HD Vendor: Amphenol Mini-SAS HD Part Number: 112-00437+A0 Mini-SAS HD Type: Passive Copper (unequalized) 2m end_1 Mini-SAS HD Serial Number: xxxxxxxxx00859 11.0 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx97F9XC) 11.1 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx5F9XC) 11.2 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxxB8F9XC) 11.3 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx95F9XC) 11.5 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx98F9XC) 11.6 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx9TF9XC) 11.7 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxxB0F9XC) 11.8 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx9NF9XC) 11.9 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx9GF9XC) 11.10: NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx9JF9XC) 11.11: NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (xxxxxx99F9XC) Shelf 11: DS212-12 Firmware rev. IOM12 A: 0281 IOM12 B: 0281
- storage show fault -v で示されているように、ディスク 2.11.4 はモジュール B によってバイパスされます。
Enclosure Status: non-criticalChannel: 0dShelf: 11Shelf Type: DS212-12Product Serial Number: xxxxxxxxxxxxxModule Type: IOM12
Disk Elements:Element Status Status Bytes Status Descriptions 4 [Bay 4]: NONCRITICAL 03,04,10,04 ENCLOSURE BYPASSED B, BYPASSED B
- ストレージの再起動後に状態がクリアされます