環境

  • FAS8200
  • FAS8300
  • FAS8700
  • FAS8020

問題

  • ONTAP CLI レポート:

::> system health subsystem show
   Environment    degraded

::> system node environment sensors show
   Node Sensor         State         Value/Units Crit-Low   Warn-Low    Warn-Hi    Crit-Hi
       PSU1 VIN     not-available   - mV      90480      93600      261040     263120
       PSU1 VOUT     not-available   - mV      11336      11440     12948     13156
       PSU1 Curr IIN    not-available   - mA     0        -         9984      12012
       PSU1 IOUT     not-available   - mA     0        -         130000     132000
       PSU1 PIN      not-available   - W      7        14        1611      1796
       PSU1 POUT     not-available   - W      7        14        1611      1796
       PSU1 Inlet      failed        - C      0        -        58      63
       PSU1 Hot      failed        - C      0        -        100      105
       PSU1 FB Hot    failed       - C      0        -        100      105
       PSU1 FAN      not-available   - RPM      800       1200      -       -

                                                                             

  • EMS ログでは、次のイベントが継続的に報告されます。

Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 VIN is Unreadable
Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 VOUT is Unreadable
Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Curr IIN is Unreadable
Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 IOUT is Unreadable
Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 PIN is Unreadable
Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 POUT is Unreadable
Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Inlet is Unreadable
Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Hot is Unreadable
Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 FB Hot is Unreadable
Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 FAN is Unreadable
Thu Sep 10 18:35:56 +0200 [Node-01: env_mgr: monitor.temp.unreadable:error]: The controller temperature (PSU1 Inlet) is not readable.
Thu Sep 10 18:35:56 +0200 [Node-01: env_mgr: monitor.temp.unreadable:error]: The controller temperature (PSU1 Hot) is not readable.
Thu Sep 10 18:35:56 +0200 [Node-01: env_mgr: monitor.temp.unreadable:error]: The controller temperature (PSU1 FB Hot) is not readable.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.