過熱が原因でシェルフ障害アラートが発生
環境
- AFF / ASA / FAS
- DS2246
- ONTAP 9
問題
EMS log
SHELF_FAULT
エラーを表示:
[FAS-01: dsa_worker0: ses.status.temperatureWarning:alert]: DS2246 (S/N XXXXXXXXXXX) shelf 5 on channel 0b temperature warning for Temperature sensor 6: non-critical status; overtemperature warning. Current temperature: 66 C (150 F). This module is on the rear of the shelf on the lower right power supply.
[FAS-01: statd: monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.
[FAS-01: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
STORAGE-FAULT
ASUPログ:
Enclosure Status: non-critical
Channel: 0b
Shelf: 5
Shelf Type: DS2246
...
Temperature Sensors:
Element Status Status Bytes Status Descriptions
1: OK 01,00,36,00
2: OK 01,00,3A,00
3: OK 01,00,3D,00
4: OK 01,00,53,00
5: OK 01,00,3C,00
6: NONCRITICAL 03,00,56,04 OT WARNING
7: OK 01,00,3E,00
8: OK 01,00,3F,00
ENVIRONMENT
ASUPログ:
温度センサー取り付けエレメントリスト:1、2、3、4、5、6、7、8;エラーあり:6
シェルフ温度エレメントごと
:[1] 34 C(93 F)(周囲温度) 通常 温度範囲[2] 38 C(100 F
)
通常温度範囲[3] 41 C(105
F)通常温度範囲[4] 63 C(145 F)通常温度範囲
-----------------
PSF-106[4][4][4][4][5]---------------------->PSU2[7]41 C(105 F)
のセンサー
通常温度範囲[8]42 C(107 F)通常温度範囲
- DC環境では過熱はありません。
- シェルフファームウェアが最新バージョンにアップグレードされている。