メインコンテンツへスキップ

PSUからDC FAIL、AC FAIL、Offが報告される

Views:
279
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
HW
Last Updated:

環境

  • AFFおよびFASシステム
  • ONTAP 9
  • 電源装置ユニット(PSU)

問題

  • EMS から次のエラーメッセージが報告されます。

[Node-A: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[Node-A: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
[Node-A: dsa_worker4: ses.status.psError:alert]: DS212-12 (S/N SHFNCXXXXXXXXXX) shelf 0 on channel 0b power error for Power supply 2: critical status; AC Fail. This module is on the rear of the shelf at the bottom right.
[Node-A: dsa_worker4: callhome.shlf.power.intr:error]: Call home for SHELF POWER INTERRUPTED

  • storage show fault に、PSUがCRITICAL であることを示します。

Power Supplies:
Element Status      Status Bytes  Status Descriptions
  1: CRITICAL      02,00,00,F1  DC FAIL, OFF, RQSTED ON, FAIL
  2: OK         01,00,00,20   RQSTED ON

または

Element Status         Status Bytes  Status Descriptions
  1: CRITICAL          02,00,00,F3   DC FAIL, AC FAIL, OFF, RQSTED ON, FAIL
  2: OK                01,00,00,20   RQSTED ON
 
Fans:
Element Status      Status Bytes  Status Descriptions
  1: CRITICAL      02,00,00,F0   OFF, FAIL
  2: CRITICAL      02,00,00,F0   OFF, FAIL
  3: OK         01,01,2C,21
  4: OK         01,01,29,21

Enclosure:
Element Status      Status Bytes  Status Descriptions
  1: OK         01,00,02,00   FAIL

Voltage Sensors:
Element Status      Status Bytes  Status Descriptions
  1: UNRECOVERABLE    04,00,00,00
  2: UNRECOVERABLE    04,00,00,00
  3: OK         01,00,01,FB
  4: OK         01,00,04,C6

  • 該当するPSUのLEDがオレンジに点灯します。

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.