Ethernet T62100-CRカードによるパニック
環境
- デュアル 40/100G Ethernet カード T62100-CR
問題
- カードに対する致命的なエラー、パニックによるフォローアップ。例:
Wed Jun 03 21:23:59 +0200 [node_name: intr: netif.fatal.err:alert]: The network device in slot 1 encountered fatal error e1a/e1b.
Wed Jun 03 21:34:06 +0200 [node_name: wafl_exempt03: sk.panic:alert]: Panic String: WAFL hung for n02_data. in SK process wafl_exempt03 on release 9.7P3 (C)
Fri Jun 05 07:28:52 +0200 [node_name: intr: netif.fatal.err:alert]: The network device in slot 1 encountered fatal error e1a/e1b.
Fri Jun 05 08:03:16 +0200 [node_name: splog_main: mgr.stack.string:notice]: Panic string: WAFL hung for n02_root. in SK process wafl_exempt12 on release 9.7P3 (C)
Tue Jun 09 10:45:33 +0200 [node_name: intr: netif.fatal.err:alert]: The network device in slot 1 encountered fatal error e1a/e1b.
Tue Jun 09 11:20:11 +0200 [node_name: splog_main: mgr.stack.string:notice]: Panic string: WAFL hung for n02_root. in SK process wafl_exempt10 on release 9.7P3 (C)
- PANIC string 例:
PANIC : PCI Error NMI from device(s):ErrSrcID(CorrSrc(0x3860),UCorrSrc(0x18)), RPT(0,3,0):PLX PCIE 8780 switch on Controller, PCI Device 1425:600d in slot 5 on Controller.
- ブートメッセージ 例:
SRAM: PCI slot5 had error, turning on slot LED.
- 致命的なエラーが発生した後、T6カードポートがダウンする、例:
slot 5: Dual 40/100G Ethernet T62100-CR
e5a MAC Address: 00:07:43:71:c5:a0 (auto-unknown-fd-down)
e5b MAC Address: 00:07:43:71:c5:a8 (auto-unknown-fd-down)
Device Type: T6 2
Firmware Version: 1.26.4.0