拡張NICカードのポートを認識できません
環境
- ONTAP 9
- NIC
問題
スロット2のEhternetポートを認識できません。
node01::> network port show
Node: node01-2
Ignore
Speed(Mbps) Health Health
Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status
--------- ------------ ---------------- ---- ---- ----------- -------- ------
e0M Default bcd_mgmt up 1500 auto/1000 healthy false
e0a Default - down 1500 auto/- - false
e0b Default - down 1500 auto/- - false
e0c Cluster Cluster up 9000 auto/25000 healthy false
e0d Cluster Cluster up 9000 auto/25000 healthy false
e1a Default - down 9000 auto/- - false
e1b Default bcd_iscsi down 1500 auto/- - false
e1c Default - down 1500 auto/- - false
e1d Default - down 1500 auto/- - false
e2a Default - down 9000 auto/- - false
e2b Default bcd_iscsi down 1500 auto/- - false
e2c Default - down 1500 auto/- - false
e2d Default - down 1500 auto/- - false
node01::> network port show
Node: node01-2
Ignore
Speed(Mbps) Health Health
Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status
--------- ------------ ---------------- ---- ---- ----------- -------- ------
e0M Default bcd_mgmt down 1500 auto/- - false
e0a Default - down 1500 auto/- - false
e0b Default - down 1500 auto/- - false
e0c Cluster Cluster up 9000 auto/25000 healthy false
e0d Cluster Cluster up 9000 auto/25000 healthy false
e1a Default - down 9000 auto/- - false
e1b Default bcd_iscsi down 1500 auto/- - false
e1c Default - down 1500 auto/- - false
e1d Default - down 1500 auto/- - false
node01::*> system node run -node * -command sysconfig -ac
2 entries were acted on.
Node: node01-1
sysconfig: slot 1 OK: X1152: 4p 25GbE RoCE SFP28
sysconfig: slot 2 OK: X1152: 4p 25GbE RoCE SFP28
sysconfig: No shelf configuration errors detected.
sysconfig: There are no configuration errors.
Node: node01-2
sysconfig: slot 1 OK: X1152: 4p 25GbE RoCE SFP28
sysconfig: No shelf configuration errors detected.
sysconfig: There are no configuration errors.