メインコンテンツまでスキップ

MCC-IPでのスイッチバック後にRAIDグループに障害が発生しました

Views:
6
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster<a>2009371342</a>
Last Updated:

環境

MCC-IP

問題

  • 計画的なメンテナンス中は、スイッチバック後にMCCのRAIDグループがオフラインになります
Aggregate aggr1 (online, raid4, mirror degraded, fast zeroed) (block checksums) Plex /aggr1/plex0 (offline, failed, inactive) RAID group /aggr1/plex0/rg0 (partial, block checksums) RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) --------- ------ ------------- ---- ---- ---- ----- -------------- -------------- parity FAILED N/A 409828/ - data 0b.10.7P1 0b 10 7 SA:A 0 SSD N/A 409828/839327744 409836/839344128 (fast zeroed) data 0b.10.8P1 0b 10 8 SA:A 0 SSD N/A 409828/839327744 409836/839344128 (fast zeroed) data 0b.10.9P1 0b 10 9 SA:A 0 SSD N/A 409828/839327744 409836/839344128 (fast zeroed) data 0b.10.0P1 0b 10 0 SA:A 0 SSD N/A 409828/839327744 409836/839344128 (fast zeroed) data 0b.10.1P1 0b 10 1 SA:A 0 SSD N/A 409828/839327744 409836/839344128 (fast zeroed) data FAILED N/A 409828/ - data FAILED N/A 409828/ - data 0b.10.4P1 0b 10 4 SA:A 0 SSD N/A 409828/839327744 409836/839344128 data FAILED N/A 409828/ - data 0b.10.10P1 0b 10 10 SA:A 0 SSD N/A 409828/839327744 409836/839344128 Raid group is missing 4 disks.
  • metrocluster operation history show レポート:
MetroCluster switchover completed with errors in auto heal. Reason: Exceeded the maximum number of retries for the command in phase Heal aggregates
  • EMS_LOG_FILE.gzには、1つ以上のドライブについて次の情報が表示されます。

raid_label_io_writeError disk_info="Disk /aggr1/plex0/rg0/0m.i1.1L4P1 Shelf 10 Bay 3

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.