SP/BMC にエラーでアクセスできません:Unable to update SP network information at this time
環境
- FAS/AFF
- ONTAP 9
- ベースボード管理コントローラ(BMC)
- サービス プロセッサ(SP)
問題
- SSH 経由で SP/BMC にアクセスできません。
- SP/BMC の IP アドレスに ping を送信できません。
- イベントログには、以下のイベントが記録されます:
splog.warnings: Could not retrieve logs from the SP for 24 hours: splogd is running in degraded mode and having difficulty getting splogs from the SP FW
[Node-1: rlm_hbtrcv_non_blocking: spmgmt.driver.timeout:error]: The software driver for the Service Processor (SP) detected a problem: Unable to update SP network information at this time.
[cluster_node0: servprocd: splog.sp.not.accessible:error]: The SP on the remote node (cluster_node1) is not accessible because of The Service Processor on node "cluster_node1" is not reachable. Verify that the SP or BMC is online, verify that api-service is enabled on the SP or BMC, verify that the partner node is running, check if pings from SP or BMC to partner node work, check if hw-assist keep-alives are normal, check that network ports are configured correctly and are functional (up). Then, try the command again..
- BMC または SP としてマークされた
sysconfig -aの出力unknown:
Service Processor Status: Online
Firmware Version: 11.5
Mgmt MAC Address: xx:xx:xx:xx:xx:xx
Ethernet Link: unknown, full duplex, auto-neg complete
Using DHCP: no
IPv4 configuration:
IP Address: unknown
Netmask: unknown
Gateway: unknown
ENVIRONMENTASUP ログにセンサー不明エラーが報告されています:
Shelf temperatures by element:
[11] Unavailable
[12] Unavailable