問題

  • イベントログには、次のシェルフ障害エラーが記録されます。

[Node-01: dsa_worker2: ses.status.ModuleError:alert]: DS212-12 (S/N SHJSG123456789) shelf 0 on channel 0b SAS expander error for SAS shelf electronics 1: critical status; Shelf ID changed. This module is on the rear of the shelf at the top left, on shelf module A.
[Node-01: dsa_worker2: ses.shelf.changedId:error]: Disk shelf module 2 on disk shelf 0b.0 indicates that the disk shelf ID has been changed since the disk shelf module was powered on. This module is on the rear of the shelf at the top right, on shelf module B.
[Node-01: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[Node-01: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT

  • AutoSupportのログに従って、シェルフIDが正しく設定されている。

::> system node run -node <node> -command sysconfig -a

Shelf 0: DS212-12  Firmware rev. IOM12E A: 0250  IOM12E B: 0250
Shelf 1: DS460-12  Firmware rev. IOM12B A: 0141  IOM12B B: 0141

  • シェルフIDの差分エラーは、シェルフの両方のモジュールで表示されます。

::> system node run -node <node> storage show fault

Enclosure Status: non-critical
Channel: 0a
Shelf: 0
Shelf Type: DS212-12
Product Serial Number: SHJSG123456789
Module Type: IOM12E

Vendor Unique Element 83-IOM12E: (SAS)
Element Status      Status Bytes  Status Descriptions
  1 [IOM12E A]   : NONCRITICAL     03,09,00,20  SHELF ID DELTA, MASTER, RESERVED
  2 [IOM12E B]   : NONCRITICAL     03,01,00,20  SHELF ID DELTA, RESERVED

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.