IOM Bに問題があるため、Sysconfig -aにシェルフIOM AのFW情報がありません
環境
- DS224C(DS224-12)
- DS212C
- IOM12、IOM12B
- ONTAP 9
問題
STORAGE-FAULTAutoSupportまたはsystem node run -node <node_name> -command storage show fault -v出力:
Enclosure Status: critical
Power Supplies:
Element Status Status Bytes Status Descriptions
1: UNKNOWN 06,00,00,A0 RQSTED ON
2: UNKNOWN 06,00,00,A0 RQSTED ON
Fans:
Element Status Status Bytes Status Descriptions
1: CRITICAL 02,00,00,F0 OFF, FAIL
2: CRITICAL 02,00,00,F0 OFF, FAIL
3: CRITICAL 02,00,00,F0 OFF, FAIL
4: CRITICAL 02,00,00,F0 OFF, FAIL
Temperature Sensors:
Element Status Status Bytes Status Descriptions
1: UNKNOWN 06,00,2E,00
2: UNKNOWN 06,00,33,00
3: UNKNOWN 06,00,33,00
4: UNKNOWN 06,00,33,00
5: UNKNOWN 06,00,33,00
6: UNKNOWN 06,00,33,00
7: UNKNOWN 06,00,35,00
8: UNKNOWN 06,00,36,00
9: UNKNOWN 06,00,36,00
10: UNKNOWN 06,00,38,00
11: UNKNOWN 06,00,3A,00
Vendor Unique Element 85-IOM12: (ACP)
Element Status Status Bytes Status Descriptions
1 [IOM12 A] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL
2 [IOM12 B] : OK 01,18,00,40 NO ACPP, INBACP, FAIL
Enclosure Electronics:
Element Status Status Bytes Status Descriptions
1 NOT INSTALLED : OK 01,00,01,00 REPORT
2: [IOM12 B] 05,00,00,00
EMSまたはevent logshow出力には、ses.status.ACPErrorイベントとmonitor.shelf.faultイベントが表示されます。
HA Group Notification (SHELF_FAULT) ERROR Manual Upload
[ses.status.ACPError:alert]: DS224-12 (S/N ) shelf 11 on channel 0a ACP Processor error for SAS shelf ACP processor 1: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top left, on shelf module A.
[statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[callhome.shlf.fault:error]: Call home for SHELF_FAULT[ses.status.ACPError:alert]: DS224-12 (S/N ) shelf 11 on channel 0b ACP Processor error for SAS shelf ACP processor 2: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top right, on shelf module B.
[ses.status.electronicsWarn:error]: DS212-12 shelf 11 on channel 0a environmental monitoring warning for SES electronics 1: not installed. This module is on the rear of the shelf at the top left.
ENVIRONMENTログは、IOM Aに挿入されたSASケーブル情報が空白であると報告します。
Channel: 0d
Shelf: 11
[1] Vendor:
Type: MINI-SAS HD passive copper 0.5-1.0m ID: 01 Swaps: 0
Serial number: Part number:
[2] Vendor:
Type: <N/A><N/A><N/A> ID: 00 Swaps: 1
Serial number: Part number:
[3] Vendor:
Type: MINI-SAS HD passive copper 0.5-1.0m ID: 00 Swaps: 0
Serial number: Part number:
[4] Vendor:
Type: <N/A><N/A><N/A> ID: 00 Swaps: 1
Serial number: Part number:
- IOM Aを取り付け直した後、
sysconfig -a出力にIOM AのFW情報が表示されない。
Example:
::> system node run -node <node_name> -command sysconfig -a
Shelf 10: DS224-12 Firmware rev. IOM12 A: 0300 IOM12 B: 0300
Shelf 11: DS224-12 Firmware rev. IOM12 A: ---- IOM12 B: 0300
- シェルフのIOM A/シャーシ/SASケーブル/PSUを交換しても問題は解決しません。
- シャーシの交換後、
ENVIRONMENTログに表示されたケーブル接続と実際の接続に不整合がありました。
Example: IOM Bは元の場所に設置されたままですが、ログにはIOM Aのスロットに挿入されていることが示されています。
シャーシ交換前
ES Electronics information by element:
[1] Serial number: NO_PSN_PRESENT_ FW= CV= Part number: AI=
CPLD version: <N/A> Swaps: 0
[2] Serial number:****67 Part number: 111-02850+C8
CPLD version: 24 Swaps: 0
シャーシ交換後
ES Electronics information by element:
[1] Serial number: ****67 Part number: 111-02850+C8
CPLD version: 24 Swaps: 0
[2] Serial number: <N/A> Part number: <N/A>
CPLD version: <N/A> Swaps: 0
- さらに、IOM AのLEDは消灯し、IOM BのLEDは点灯していますが、IOM Bのファームウェア情報が
sysconfig-aログに表示されなくなります。 - 2台のIOMを別のシェルフにスワップすると、問題が再現されます。