問題
- 埋め込みシェルフファームウェアを更新できません:
node_name-2 ERROR sfu.firmwareDownrev: Disk shelf firmware needs to be updated on 1 disk shelf.
node_name-2 ERROR sfu.firmwareDownrev.shelf: Shelf 0a.shelf0 has downrev firmware.
node_name-2 ERROR sfu.downloadSummaryErrors: Shelf firmware updated on 0 shelves, failed to update on 1 shelf.
node_name-2 ERROR sfu.downloadError: [storage download shelf]: Error downloading firmware file IOM12E.0230.SFW on 0a.shelf0.General firmware update error.
node_name-2 ERROR sfu.SASDownloadFailed: [storage download shelf]: Download failed on IOM12E.0230.SFW on disk shelf controller module A on disk shelf 0a.0.
node_name-2 ERROR scsi.cmd.checkCondition: Enclosure services device 0a.00.99: Check Condition: CDB 0x1d: Sense Data SCSI:illegal request - (0x5 - 0x35 0x4 0x0)(946).
node_name-2 ERROR sfu.firmwareDownrev: Disk shelf firmware needs to be updated on 1 disk shelf.
node_name-2 ERROR sfu.firmwareDownrev.shelf: Shelf 0a.shelf0 has downrev firmware.
node_name-2 ERROR sfu.downloadSummaryErrors: Shelf firmware updated on 0 shelves, failed to update on 1 shelf.
node_name-2 ERROR sfu.downloadError: [storage download shelf]: Error downloading firmware file IOM12E.0230.SFW on 0a.shelf0.Subenclosure status error.General firmware update error.
node_name-2 ERROR sfu.firmwareDownrev: Disk shelf firmware needs to be updated on 1 disk shelf.
- 1つのノード、時間単位のレポート:
...
[node_name-1: dsa_disc: sfu.firmwareDownrev.shelf:error]: Shelf 0a.shelf0 has downrev firmware.
[node_name-1: dsa_disc: sfu.firmwareDownrev.shelf:error]: Shelf 0a.shelf0 has downrev firmware
- パートナーノード2のレポート:
...
[node_name-2: dsa_disc: sfu.firmwareDownrev.shelf:error]: Shelf 0a.shelf0 has downrev firmware.
[node_name-2: dsa_sfu: sfu.firmwareDownrev:error]: Disk shelf firmware needs to be updated on 1 disk shelf.
[node_name-2: dsa_sfu: sfu.downloadStarted:info]: Update of disk shelf firmware started on 1 shelf.
[node_name-2: dsa_worker4: sfu.ctrllerElmntsPerShelf:info]: [storage download shelf]: 2 ES controller elements can be updated on 0a.shelf0.
[node_name-2: dsa_worker4: sfu.downloadingController:info]: [storage download shelf]: Downloading IOM12E.0240.SFW on disk shelf controller module A on 0a.shelf0.
[node_name-2: dsa_sfu: sfu.SASDownloadFailed:error]: [storage download shelf]: Download failed on IOM12E.0240.SFW on disk shelf controller module A on disk shelf 0a.0.
[node_name-2: dsa_sfu: ses.status.cmdblk:debug]: Firmware update failed on disk shelf 0a.0. Status of the command block for the failed command [storage download shelf]: CDB 0x1d; target 0x2; ha 0x0; out_status_flags 0x24; sense_key 0x5; sense_code 0x35; sense_code_qualifier 0x4.
[node_name-2: dsa_sfu: sfu.downloadError:error]: [storage download shelf]: Error downloading firmware file IOM12E.0240.SFW on 0a.shelf0.General firmware update error.
[node_name-2: dsa_sfu: sfu.downloadSummaryErrors:error]: Shelf firmware updated on 0 shelves, failed to update on 1 shelf.