問題

次のログでは、アンプラグは 13 : 16 : 27 であることがわかりますが、ポートリンクは 13 : 17 : 33 で識別されています。

 
ping コマンドの出力:
"OK","2020/10/09 13:16:26","172.27.17.11","172.27.17.11","Time: 0ms",""
"NG","2020/10/09 13:16:27","172.27.17.11","","Request timed out",""
……
"NG","2020/10/09 13:17:36","172.27.17.11","","Request timed out",""
"OK","2020/10/09 13:17:37","172.27.17.11","172.27.17.11","Time: 0ms",""
 
EMS
[?] Fri Oct 09 13:17:33 +0900 [p-dc2-fas-01-01: mgmt_port_link_status_poll: netif.linkDown:info]: Ethernet Wrench Port: Link down, check cable.
[?] Fri Oct 09 13:17:36 +0900 [p-dc2-fas-01-01: vifmgr: vifmgr.portdown:notice]: A link down event was received on node p-dc2-fas-01-01, port e0M.
[?] Fri Oct 09 13:17:36 +0900 [p-dc2-fas-01-01: vifmgr: vifmgr.lifdown.noports:alert]: LIF p-dc2-fas-01-01_mgmt1 (on virtual server 4294967295), IP address 172.27.17.12, currently cannot be hosted on node p-dc2-fas-01-01, port e0M, or any of its failover targets, and is being marked as down.
[?] Fri Oct 09 13:17:36 +0900 [p-dc2-fas-01-01: vifmgr: vifmgr.lifBeingRemoved:notice]: LIF p-dc2-fas-01-01_mgmt1 (on virtual server 4294967295), IP address 172.27.17.12, is being removed from node p-dc2-fas-01-01, port e0M.
[?] Fri Oct 09 13:17:36 +0900 [p-dc2-fas-01-01: vifmgr: vifmgr.lifmoved.linkdown:notice]: LIF cluster_mgmt (on virtual server 4294967295), IP address 172.27.17.11, is being moved to node p-dc2-fas-01-02, port e0M.
[?] Fri Oct 09 13:17:36 +0900 [p-dc2-fas-01-01: vifmgr: vifmgr.lifBeingRemoved:notice]: LIF cluster_mgmt (on virtual server 4294967295), IP address 172.27.17.11, is being removed from node p-dc2-fas-01-01, port e0M.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.