環境

  • FAS2552
  • ONTAP 8.3.2P2

問題

  • ノードをブートできず、コンソールにMCAエラーが表示される。

MCA ERROR
MSR:00000421:CC106380_0001009F
GFERR: 00000000

  • ECC error at DIMM SPシステムログを参照できます。
NetApp Data ONTAP 8.3.2P2

Copyright (C) 1992-2016 NetApp.

All rights reserved.

Checking boot device filesystem

** /dev/da0s1

** Phase 1 - Read and Compare FATs

** Phase 2 - Check Cluster Chains

** Phase 3 - Checking Directories

** Phase 4 - Checking for Lost Files

63 files, 1071456 free (33483 clusters)

MARK FILE SYSTEM CLEAN? yes

MARKING FILE SYSTEM CLEAN

Retry #1 of 5: /sbin/fsck_msdosfs /dev/da0s1

Retry #2 of 5: /sbin/fsck_msdosfs /dev/da0s1

Repaired boot device filesystem

*******************************

*                             *

* Press Ctrl-C for Boot Menu. *

*                             *

*******************************   

ECC error at DIMM-1: 94-01-1637-0300F965,ADDR 0x3f7e2980,(Node(0), CH(0), DIMM(0), Rank(0), Bank(0x7),Row(0x1f7c), Col(0x130)

Syndrome(Correctable Errors)DQ(63), xfer( 2)


Correctable Machine Check Error at CPU2. NB Error: STATUS(Val,MiscV,AddrV,CErrCnt(0x1),RdECC,ErrCode(Channel Unkn, Read)ErrCode(0x9f))MISC(Synd(0x38ac1608),Chan(0),DIMM(0),RTID(0x3)), ADDR(0x3f7e2980).

ECC error at DIMM-1: 94-01-1637-0300F965,ADDR 0x97dda80,(Node(0), CH(0), DIMM(0), Rank(1), Bank(0x6),Row(0x96b), Col(0x350)

Syndrome(Correctable Errors)DQ(63), xfer( 2)
  • の出力で system helath alert show は、DIMM creitical errorが報告されています。

::> system health alert show

           Node: node2
      Resource: DIMM-1
      Severity: Critical
   Indication Time: Fri Dec 22 04:54:10 2023
      Suppress: false
     Acknowledge: false
   Probable Cause: The DIMM has reached end of life, which is leading to
           memory errors.
   Possible Effect: Memory issues can lead to a catastrophic system panic
           which can lead to data downtime on the node.
Corrective Actions: 1. Contact technical support to obtain a new DIMM of the same specification.
           2. If possible, perform a takeover of this node and bring the node down for maintenance.
           3. Refer to the "DIMM replacement guide for your given hardware platform" to replace the DIMM.
           4. Bring the storage system online.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.