マザーボードの交換後にスイッチバックできません
- Views:
- 11
- Visibility:
- Public
- Votes:
- 0
- Category:
- fas-systems<a>2009345870</a>
- Specialty:
- metrocluster
- Last Updated:
環境
- AFF & FAS の略
- ONTAP 9
- 2ノードのストレッチMetroCluster
問題
- マザーボードの交換が完了したあとにスイッチバックを実行できない:
clusterA::> metrocluster switchback -simulate [Job 001] Setting up the node and cluster components for the switchback operation...[Job 001] Job failed: Failed to set up the node and cluster components for the switchback operation. Use the "metrocluster operation show" command to view detailed error information. Resolve the errors, then try the command again.
clusterA::> metrocluster operation show Operation: switchback-simulate State: failed Start Time: 10/27/2022 11:34:27 End Time: 10/27/2022 11:35:09 Errors: Failed to set up the node and cluster components for the switchback operation. clusterA (fatal): Configuration replication service is not ready in cluster "clusterB". Wait a few minutes, then try the command again.
- スイッチオーバー時に障害ノードが認識しません。
clusterB::> metrocluster show
Configuration: stretch
Cluster Entry Name State ------------------------------ ---------------------- --------------------- Local: clusterB Configuration State configured Mode normal AUSO Failure Domain auso-on-cluster-disaster Remote: clusterA Configuration State configured Mode switchover AUSO Failure Domain auso-on-cluster-disaster