ONTAP のアップグレード後に、NS224 NSMでサポートされないスイッチアラートが発生します
環境
- NS224シェルフ
- ONTAP を9.10.1P3以降のバージョンにアップグレードします。
問題
- 9.10.1P3+へのアップグレード後にSystem Healthアラートエラーが表示される:
::> system health alert show
Node: node_name
Alert ID: SwitchCommunityString_Alert
(aa:bb:cc:dd:ee:ff) 0000.1111.2222.3333
Severity: Major
...
Probable Cause: Ethernet switch "0000.1111.2222.3333
(aa:bb:cc:dd:ee:ff)" with IP address "192.168.0.1" is
not reachable via SNMP. Incorrect SNMP community
string might be configured on the Ethernet switch.
Possible Effect: Ethernet switch communication problems and
accessibility issues.
Corrective Actions: Check the SNMP community string on the Ethernet switch
to verify that the expected community string is
configured. Use the "system switch ethernet show
-snmp-config" command to view the expected community
string.
Node: node_name
Alert ID: UnsupportedSwitch_Alert
(aa:bb:cc:dd:ee:ff) 0000.1111.2222.3333
Severity: Major
...
Probable Cause: Unsupported Ethernet switch is detected.
Possible Effect: Communication problems and network connectivity issues
occur.
Corrective Actions: Unsupported Ethernet switch "0000.1111.2222.3333
(aa:bb:cc:dd:ee:ff)" found. Connect a supported
Ethernet switch to the network.
2 entries were displayed.
::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor ok
Switch-Health degraded
- NS224シェルフは、LLDPを使用してストレージネットワークスイッチとして検出されます。
::> system switch ethernet show
Switch Type Address Model
--------------------------- ------------------ ---------------- ---------------
(aa:bb:cc:dd:ee:ff) storage-network 192.168.0.1 OTHER
Serial Number: Unknown
Is Monitored: false
(aa:bb:cc:dd:ee:ff) Model: OTHER is not qualified in a storage-network
Software Version: NetApp NS000.NSM000.SH00.A (v.0000)
Version Source: LLDP