メインコンテンツまでスキップ

クラスタネットワークで ping を実行する場合、 Vifmgr.cluscheck.droppedall

Views:
172
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
HW
Last Updated:

環境

  • ONTAP 9
  • スイッチ クラスタ
  • SFP接続用のケーブル配線

問題

  • ems-log または Via で報告される問題:
 
::> event log show -message-name vifmgr.cluscheck*
 

node1 NOTICE vifmgr.cluscheck.droppednone: No packet loss when pinging from cluster lif node1lif (node node1) to cluster lif node2lif (node node2).

node1 ALERT vifmgr.cluscheck.droppedall: Total packet loss when pinging from cluster lif node1lif (node node1) to cluster lif node2lif (node node2).
 
  • クラスタネットワークは正常な状態です。

 ::> network interface  show -vserver Cluster


       Logical   Status    Network       Current  Current Is
Vserver    Interface  Admin/Oper Address/Mask     Node    Port   Home
----------- ---------- ---------- ------------------ ------- -------  ----
Cluster
       node1       up/up   169.254.49.XX/16   node1    e0a   true
       node2       up/up   169.254.69.XX/16   node2    e0b   true
       node3       up/up   169.254.150.XX/16  node3    e0a   true
       node4       up/up   169.254.234.XX/16  node4    e0b   true
       node5       up/up   169.254.5.XX/16   node5    e0a   true
       node6       up/up   169.254.99.XX/16   node6    e0b   true
       node7       up/up   169.254.103.XX/16  node7    e0a   true
       node8       up/up   169.254.194.XX/16  node8    e0b   true

cluster1::> network port show -ipspace Cluster

Node: node1
                                    Ignore
                          Speed(Mbps) Health   Health
Port    IPspace    Broadcast Domain Link MTU  Admin/Oper  Status   Status
--------- ------------ ---------------- ---- ---- ----------- -------- ------
e0a     Cluster    Cluster      up   9000  auto/10000 healthy false
e0b     Cluster    Cluster      up   9000  auto/10000 healthy false

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.