問題
- storage failover showに「storage failover mailbox disk state is invalid、local node missing partner disks」と表示され、パートナー名がありません:
Node Name as Returned by Storage Failover Component: Node1 Partner Name: - Node NVRAM ID: 538241368 Partner NVRAM ID: 538241280 Takeover Enabled: true HA Mode: ha Takeover Possible: false Reason Takeover not Possible: Storage failover mailbox disk state is invalid Local node missing partner disks Reason Takeover not Possible (Enum value): mailbox_invalid disk_inventory_mismatch_local Interconnect Up: true Interconnect Links: RDMA Interconnect is up Interconnect Type: RoCE State Description: Connected to partner, Takeover is not possible: Storage failover mailbox disk state is invalid, Local node missing partner disks Partner State: Up
- プレーンテキストボリュームをNVEボリュームに変換しようとすると、次のようなエラーが表示されて失敗します。
::> volume encryption conversion start -vserver vserver1 -volume vol0 Error: command failed: Failed to start conversion on volume "vol0" in Vserver "vserver1". Reason: Internal error. Use the "cluster show" command to verify that all nodes are healthy. Wait a few minutes and try the operation again.