メインコンテンツへスキップ

シェルフに「OT WARNING」、「Overtemperature warning」、または「callhome.chassis.hitemp」のアラートが表示されます。

Views:
138
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

環境

  • FAS2620
  • FAS2720

問題

  • シャーシの過熱エラーは、イベントログに1時間ごとに記録されます:

[Node1: env_mgr: monitor.chassisTemperature.warm:alert]: Chassis temperature is too warm: Ambient Temp is critical high (120 C).
[Node1: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.

[Node1: env_mgr: monitor.chassisTemperature.warm:alert]: Chassis temperature is too warm: Midplane 4 Temp is warning high (47 C).
[Node1: env_mgr: monitor.chassisTemperature.warm:alert]: Chassis temperature is too warm: Midplane 3 Temp is warning high (47 C).
[Node1: monitor: monitor.globalStatus.critical:EMERGENCY]: Chassis temperature is too high.. 
[Node1: env_mgr: callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE

  • シェルフのいくつかの センサーが温度超過を報告しています:

::> system node run -node <node> -command storage show fault

Enclosure Status: non-critical
Channel: 0b
Shelf: 0
Shelf Type: DS224-12
Product Serial Number: SHFFG1914000066
Module Type: IOM12E

Temperature Sensors:
Element Status         Status Bytes  Status Descriptions
  1: OK                01,00,33,00   
  2: OK                01,00,39,00   
  3: OK                01,00,39,00   
  4: NONCRITICAL       03,00,44,04   OT WARNING
  5: NONCRITICAL       03,00,44,04   OT WARNING
  6: OK                01,00,3F,00  
 

  • 過熱警告は環境ログにも表示されます:

::> system node run -node <node> -command environment status

Temperature Sensor installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15; with error: 4, 5
    Shelf temperatures by element:
      [1] 31 C (87 F) (ambient)  Normal temperature range
      [2] 37 C (98 F)  Normal temperature range
      [3] 37 C (98 F)  Normal temperature range
      [4] 48 C (118 F) Overtemperature warning!
      [5] 48 C (118 F) Overtemperature warning!
      [6] 43 C (109 F)  Normal temperature range

  • SPセンサーログから:

Sensor Name              State          Current    Critical     Warning     Warning    Critical
                                        Reading       Low         Low         High       High
-------------------------------------------------------------------------------------------------
Temp Low Shutdown                           UP
Temp High Shutdown                          UP
SNMP Bad Fan Count                          OK
Chassis is Under Temp                       NO
Chassis is Over Temp                      YES

Midplane 4 Temp          warnhigh          47 C        0 C         5 C        47 C        52 C     
Midplane 3 Temp          warnhigh          47 C        0 C         5 C        47 C        52 C     
Midplane 2 Temp          normal            36 C         0 C         5 C        47 C        52 C     
Midplane 1 Temp          normal            36 C         0 C         5 C        47 C        52 C     

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.