環境
- Fabric MetroCluster の略
- ONTAP 7 モード
問題
- 複数のドライブが複数のノードからチェックサムエラーを報告している
Mon Nov 15 11:43:36 CET [node-01: disk_server_0: disk.checksum.verifyFailed:error]: Disk level checksum verification failed on WRITE VERIFY: Disk sw4:5.126L132, Block #90468901: Volume vol1, FileId 73, Block #6465
Mon Nov 15 11:43:42 CET [node-01: disk_server_1: disk.checksum.verifyFailed:error]: Disk level checksum verification failed on WRITE VERIFY: Disk sw4:5.126L38, Block #197881793: Volume vol2, FileId 101, Block #38003369
Mon Nov 15 11:43:42 CET [node-01: disk_server_0: disk.checksum.verifyFailed:error]: Disk level checksum verification failed on WRITE VERIFY: Disk sw4:5.126L45, Block #214050274: Volume vol3, FileId 97, Block #1853207023
Mon Nov 15 11:43:56 CET [node-01: disk_server_0: disk.checksum.verifyFailed:error]: Disk level checksum verification failed on WRITE VERIFY: Disk sw4:5.126L152, Block #218915150: Volume vol4, FileId 101, Block #1046572
Mon Nov 15 11:44:01 CET [node-01: disk_server_0: disk.checksum.verifyFailed:error]: Disk level checksum verification failed on WRITE VERIFY: Disk sw4:5.126L185, Block #84031152: Volume vol5, FileId 97, Block #1304767822
Mon Nov 15 11:44:08 CET [node-01: disk_server_0: disk.checksum.verifyFailed:error]: Disk level checksum verification failed on WRITE VERIFY: Disk sw4:5.126L254, Block #9475108: Volume vol5, FileId 97, Block #594239028
Mon Nov 15 11:44:15 CET [node-01: disk_server_0: disk.checksum.verifyFailed:error]: Disk level checksum verification failed on WRITE VERIFY: Disk sw4:5.126L248, Block #209441865: Volume vol6, FileId 101, Block #6735845
Mon Nov 15 11:44:27 CET [node-01: disk_server_0: disk.checksum.verifyFailed:error]: Disk level checksum verification failed on WRITE VERIFY: Disk sw4:5.126L139, Block #179664210: Volume vol7, FileId 98, Block #68726647296
Mon Nov 15 11:44:36 CET [node-01: disk_server_1: disk.checksum.verifyFailed:error]: Disk level checksum verification failed on WRITE VERIFY: Disk sw4:5.126L132, Block #6005141: Volume vol4, FileId 101, Block #1048263
Mon Nov 15 11:44:42 CET [node-01: disk_server_0: disk.checksum.verifyFailed:error]: Disk level checksum verification failed on WRITE VERIFY: Disk sw4:5.126L242, Block #165234200: Volume vol8, FileId 97, Block #1084249415
Mon Nov 15 11:46:04 CET [node-01: disk_server_1: disk.checksum.verifyFailed:error]: Disk level checksum verification failed on WRITE VERIFY: Disk sw4:5.126L239, Block #190357718: Volume vol5, FileId 97, Block #1861448895
- ドライブが使用停止になっている可能性もあります
- エラーはすべて同じスイッチから報告されます
- ATTO ブリッジのログまたはスイッチのログにエラーは表示されません