  • EMS PSUの電源低下エラーを検出します。
[?]  Tue Sep 24 07:45:11 +0900 [Node: env_mgr: monitor.chassisPowerSupply.off:notice]: Chassis power supply 2 off.
[?]  Tue Sep 24 07:45:11 +0900 [Node: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Crest Factor is Critical Low (0)
[?]  Tue Sep 24 07:45:17 +0900 [Node: power_low_monitor: monitor.chassisPower.degraded:alert]: Chassis power is degraded: Power Supply Status Critical: PSU2.
[?]  Tue Sep 24 07:45:17 +0900 [Node: power_low_monitor: callhome.chassis.power:error]: Call home for CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU2.
[?]  Tue Sep 24 07:45:28 +0900 [Node: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'adapterName': '1', 'debug_string': 'Adapter debug dump is being collected'}
[?]  Tue Sep 24 07:45:28 +0900 [Node: pmcsas_asyncd_1: sas.adapter.debug:info]: params: {'adapterName': '0a', 'debug_string': 'Adapter debug dump is being collected'}
[?]  Tue Sep 24 07:45:40 +0900 [Node: env_mgr: callhome.chassis.ps.off:error]: Call home for CHASSIS POWER SUPPLY OFF: PS 2
[?]  Tue Sep 24 07:46:00 +0900 [Node: monitor: monitor.globalStatus.critical:EMERGENCY]: Power Supply Status Critical: PSU2.
[?]  Tue Sep 24 07:46:02 +0900 [Node: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Temperature is Unreadable
[?]  Tue Sep 24 07:46:02 +0900 [Node: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Current is Unreadable
[?]  Tue Sep 24 07:46:02 +0900 [Node: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Fan1 Speed is Unreadable
[?]  Tue Sep 24 07:46:02 +0900 [Node: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Fan1 Fault is Unreadable
[?]  Tue Sep 24 07:46:02 +0900 [Node: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Fan2 Speed is Unreadable
[?]  Tue Sep 24 07:46:02 +0900 [Node: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Fan2 Fault is Unreadable
[?]  Tue Sep 24 07:46:03 +0900 [Node: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Pwr Out OK is Unreadable
[?]  Tue Sep 24 07:46:03 +0900 [Node: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Fault is Unreadable
[?]  Tue Sep 24 07:46:03 +0900 [Node: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Over Temp is Unreadable
[?]  Tue Sep 24 07:46:03 +0900 [Node: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Over Volt is Unreadable
[?]  Tue Sep 24 07:46:03 +0900 [Node: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Over Curr is Unreadable
[?]  Tue Sep 24 07:46:12 +0900 [Node: env_mgr: callhome.chassis.ps.degraded:error]: Call home for CHASSIS POWER SUPPLY DEGRADED: PS 2
 
  • SP-LATEST-IPMI 複数のPSUセンサーのステータスがna と表示されます。 
hsamcmd --fault-show-all
===============================
tag  origin  fld                   fault reason                   count  time
---- ------- ----                   -------------                  ------ -----
1   0x5   /chassis-1/power-2            Voltage Sensor 85 Power Good           1    Mon Sep 23 22:44:38 2024
2   0x5   /chassis-1/power-2            Current Sensor 225 LNC              1    Mon Sep 23 22:44:39 2024
3   0x5   /chassis-1/power-2            Current Sensor 225 LCR              1    Mon Sep 23 22:44:40 2024
 
PSU2_Present   | 0x0     | discrete  | Present   | na     | na     | na     | na
PSU2_Temp     | na     | degrees C  | na     | 0.000   | 5.000   | 50.000   | 60.000
PSU2_Curr     | na     | Amps    | na     | na     | na     | na     | na
PSU2_Fan1_Speed  | na     | RPM     | na     | 4500.000  | 4600.000  | na     | na
PSU2_Fan1_Fault  | na     | discrete  | na     | na     | na     | na     | na
PSU2_Fan2_Speed  | na     | RPM     | na     | 4500.000  | 4600.000  | na     | na
PSU2_Fan2_Fault  | na     | discrete  | na     | na     | na     | na     | na
PSU2_Status    | na     | discrete  | na     | na     | na     | na     | na
PSU2_Pwr_In_OK  | 0x0     | discrete  | Deasserted | na     | na     | na     | na
PSU2_Pwr_Out_OK  | na     | discrete  | na     | na     | na     | na     | na
PSU2_Fault    | na     | discrete  | na     | na     | na     | na     | na
PSU2_Input_Type  | na     | discrete  | na     | na     | na     | na     | na
PSU2_Over_Temp  | na     | discrete  | na     | na     | na     | na     | na
PSU2_Over_Volt  | na     | discrete  | na     | na     | na     | na     | na
PSU2_Over_Curr  | na     | discrete  | na     | na     | na     | na     | na
PSU2_CrestFactor | 0.000    | unspecified | cr     | 1.000   | 1.000   | 1.728   | 2.000
PSU2_InPwr_Mon  | 0.000    | Watts    | ok     | na     | na     | na     | na
  • STORAGE-FAULT、発行されたPSUのエラーが表示されないことがあります。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.