ディスクを交換して再配置したあとにストレージプールがデグレードステータスになっています
環境
- ハイブリッド アグリゲート
- ストレージ プール
問題
storage pool show
出力例:
GIJNETAPP::> storage pool show -instance
Storage Pool Name: storage_pool_name
UUID of Storage Pool: 0000a0bc-000a-00a0-abc0-00a0000000bc
Nodes Sharing the Storage Pool: node_name2,node_name1
Number of Disks in Storage Pool: 3
Allocation Unit Size: 279.2GB
Allocation Unit Data Size for RAID4: 186.2GB
Allocation Unit Data Size for RAID-DP: 93.08GB
Allocation Unit Data Size for RAID-TEC: -
Storage Type: SSD
Storage Pool Usable Size: 0B
Storage Pool Total Size: 1.09TB
Is Pool Healthy?: false
State of the Storage Pool: degraded
Reason for Storage Pool Being Unhealthy: Storage pool has more number of disks than expected.
Job ID of the Currently Running Operation:
- ストレージプールの RAID グループと SSD でエラーは発生しません。
Aggregate aggregate1 (online, raid_dp, hybrid) (block checksums)
Plex /aggregate1/plex0 (online, normal, active, pool0)
RAID group /aggregate1/plex0/rg0 (normal, block checksums)
RAID group /aggregate1/plex0/rg1 (normal, block checksums)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 0a.00.0P1 0a 0 0 SA:A 0 SSD N/A 95312/195200512 95320/195216896
parity 0a.00.3P4 0a 0 3 SA:A 0 SSD N/A 95312/195200512 95320/195216896
data 0a.00.2P1 0a 0 2 SA:A 0 SSD N/A 95312/195200512 95320/195216896
RAID group /aggregate1/plex0/rg2 (normal, block checksums)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 0a.00.0P2 0a 0 0 SA:A 0 SSD N/A 95312/195200512 95320/195216896
parity 0a.00.3P3 0a 0 3 SA:A 0 SSD N/A 95312/195200512 95320/195216896
data 0a.00.2P2 0a 0 2 SA:A 0 SSD N/A 95312/195200512 95320/195216896
Aggregate aggregate2 (online, raid_dp, hybrid) (block checksums)
Plex /aggregate2/plex0 (online, normal, active, pool0)
RAID group /aggregate2/plex0/rg0 (normal, block checksums)
RAID group /aggregate2/plex0/rg1 (normal, block checksums)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 0a.00.0P3 0a 0 0 SA:B 0 SSD N/A 95312/195200512 95320/195216896
parity 0a.00.3P2 0a 0 3 SA:B 0 SSD N/A 95312/195200512 95320/195216896
data 0a.00.2P3 0a 0 2 SA:B 0 SSD N/A 95312/195200512 95320/195216896
RAID group /aggregate2/plex0/rg2 (normal, block checksums)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 0a.00.0P4 0a 0 0 SA:B 0 SSD N/A 95312/195200512 95320/195216896
parity 0a.00.3P1 0a 0 3 SA:B 0 SSD N/A 95312/195200512 95320/195216896
data 0a.00.2P4 0a 0 2 SA:B 0 SSD N/A 95312/195200512 95320/195216896
GIJNETAPP::> storage pool show-disks
Storage Pool Name: storage_pool_name
Disk
Disk Type Usable Size Total Size
-------- ------- ----------- -----------
1.0.1 SSD 372.4GB 372.6GB
1.0.2 SSD 372.4GB 372.6GB
1.0.3 SSD 372.4GB 372.6GB
3 entries were displayed.